--- title: "Passive fail-open switches" slug: "passive-fail-open-switches" tags: ["Product Usage", "IPS 10.1.10"] updated: 2026-10-05T15:40:40Z published: 2026-10-05T15:40:40Z canonical: "docs.trellix.com/passive-fail-open-switches" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Passive fail-open switches A passive fail-open switch depends on the Sensor to send a control signal or heartbeat signal from its **Control** port at regular intervals. A passive copper or fiber fail-open switch receives a control signal every second. If the fail-open switch does not receive a signal for 4 seconds consecutively, it transitions to bypass mode thereby removing the Sensor from the path of traffic. During normal operation, the bypass status of the switch remains ON. To confirm this, you must see the **Control** port LED ON on the switch. When the Sensor fails or reboots, bypass status is activated, which is indicated by the **Control** port LED going off. When the fail-open switch is in bypass mode, there is no traffic monitoring by the Sensor. > [!NOTE] > Note > > Passive fail-open kits are not compatible with NS9500, NS9x00, NS3500 and NS3x00 Sensors since these Sensors do not have control ports. Refer to the table which lists all fail-open switches and the Sensors with which they are compatible for more details.