The new docs.trellix.com features a modernized UI and AI-powered conversational search. Content is currently available in English, with additional languages launching in early November 2026. We hope you enjoy the updated experience.

raidrepair

Prev Next

This command repairs the RAID1 SSD component exhibiting a fault. Select raidrepair current <ssd0|ssd1> to repair the faulty SSD within the Sensor.

Select raidrepair new <ssd0|ssd1> to replace the faulty SSD with a new SSD, and to restore the data on RAID1 it synchronizes the data of the healthy SSD with the new SSD.

Note

RAID is not supported on NS9600, NS7600, NS7500, NS7x50, NS7x00, NS5x00, NS3600, NS3500, and NS3x00 Sensors.

Syntax:

raidrepair <new|current> <ssd0|ssd1>

Parameter

Description

new

When a complete reimage of a single disk is required

current

When the disk is corrupted

ssd0

Disk is located in the upper bay within the chassis.

ssd1

Disk is located in the lower bay within the chassis.

Applicable to:

NS9500, NS9300, NS9200, and NS9100 Sensors