title: "raidrepair"
slug: "raidrepair"
tags: ["Product Usage", "IPS 10.1.10"]
updated: 2026-10-05T15:40:56Z
published: 2026-10-05T15:40:56Z
canonical: "docs.trellix.com/raidrepair"
---
> ## Documentation Index
> Fetch the complete documentation index at: https://docs.trellix.com/llms.txt
> Use this file to discover all available pages before exploring further.
# raidrepair
This command repairs the RAID1 SSD component exhibiting a fault. Select raidrepair current <ssd0|ssd1> to repair the faulty SSD within the Sensor.
Select raidrepair new <ssd0|ssd1> to replace the faulty SSD with a new SSD, and to restore the data on RAID1 it synchronizes the data of the healthy SSD with the new SSD.
> [!NOTE]
> Note
>
> RAID is not supported on NS7500, NS7x50, NS7x00, NS5x00, NS3500, and NS3x00 Sensors.
**Syntax:**
raidrepair <new|current> <ssd0|ssd1>
| Parameter | Description |
| --- | --- |
| new | When a complete reimage of a single disk is required |
| current | When the disk is corrupted |
| ssd0 | Disk is located in the upper bay within the chassis. |
| ssd1 | Disk is located in the lower bay within the chassis. |
**Applicable to:**
NS9500, NS9300, NS9200, and NS9100 Sensors