--- title: "Remove an active fail-open switch from the chassis" slug: "remove-an-active-fail-open-switch-from-the-chassis" tags: ["Hardware", "IPS 11.1.x"] updated: 2026-09-17T07:33:43Z published: 2026-09-17T07:33:43Z canonical: "docs.trellix.com/remove-an-active-fail-open-switch-from-the-chassis" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Remove an active fail-open switch from the chassis **Prerequisite:** You must make sure the fail-open switch is fully powered off before you attempt to remove it from the chassis. Follow the steps in this section to power off and remove the fail-open switch. **Steps:** 1. Power off the fail-open switch using the web interface or CLI command prompt. - If you are using the web interface, click the **Rescue** tab and check the **Power Off** checkbox in the **System Restore** section. To access the web interface, refer to the section [Access the fail-open switch web interface](/network-and-platform/docs/manage-the-fail-open-switch-through-a-web-interface). ![GUID-B20138F3-1C48-4D58-81E2-9159A7B7E415-low.jpg](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-761593b8-9257-e13e-9f96-50a5f8d9753d.jpg?sv=2026-02-06&spr=https&st=2026-11-20T18%3A51%3A33Z&se=2026-11-20T19%3A51%3A33Z&sr=c&sp=r&sig=cqNlTwEvC%2F5jDrnK0zByKi7pa1zlDGIz5dIpScAoUVM%3D) - If you are using the CLI command prompt, type `power_off` and press **Enter**. To access the CLI prompt, refer to the section [Configure fail-open switch parameters](/network-and-platform/docs/configure-fail-open-switch-parameters). 2. When the fail-open switch is powered off, remove the captive screws and slide it out of the chassis.