Resolved Manager software issues

The following table lists the medium-severity Manager software issues:

Reference #

Resolution

NSPMGR-27357

An attempt to import invalid licenses fails and the existing licenses disappear for Virtual Sensors in the Manager → <Admin Domain Name> → Setup → Licenses page.

NSPMGR-27315

Error occurs while creating or deleting HA pairs in the Manager, when Integration with Trellix Network Investigator is enabled.

NSPMGR-27303

Upgrade from software version 10.1.7.65 to 11.1.7.26 fails in Linux-based Manager.

NSPMGR-27278

Any change made in the Master Attack repository from IPS Central Manager or associated Managers does not reflect in the Policy → <Admin Domain Name> → Intrusion Prevention → Policy Types → IPS page.

NSPMGR-27260

Jumbo frame parsing and SSL decryption features get disabled in stack HA Sensors after upgrading to Sensor version 11.1.5.57.

NSPMGR-27247

Syslog messages show incorrect Interface names for member Sensors when NS9500 Sensors in stacks are configured with the Manager with syslog notification enabled.

NSPMGR-27207

Unable to export Sensor configuration using the Devices → <Admin Domain Name> → Devices → <Device Name> → Maintenance → Export Configuration page.

NSPMGR-27192

After configuring email server details in the Manager → <Admin Domain Name> → Setup → E-mail Server page and saving the changes, an error is displayed in the Manager on clicking the Test Connection button stating that the email server details are not saved.

NSPMGR-27173

Memory usage chart shows different values on loading and after refresh on the Memory tab in the Devices → <Admin Domain Name> → Devices → <Device Name> → Troubleshooting → Performance Charts page when Decrypted Flow Pool is selected as the metric.

NSPMGR-20340

After upgrading the stack Sensor software version from the Device Manager page, the Sensor fails to reboot automatically.

Resolved Sensor software issues

The following table lists the high-severity Sensor software issues:

Reference #

Resolution

NSPSNSR-14946

A process crash is observed when Client Browser Detection is enabled for Web Server - Denial-of-Service Protection feature and while parsing the jumbo frames.

The following table lists the medium-severity Sensor software issues:

Reference #

Resolution

NSPSNSR-15260

Latency Alerts are observed with Sensor version 10.1.5.190 and later due to incorrect shared memory alignment in software.

NSPSNSR-15126

l7ae.console log file size becomes very big as the log rotation fails after upgrading the Sensor to version 11.1 or later.

NSPSNSR-14448

HTTP traffic on the non-standard destination ports is permitted despite the Quarantine Zone rules in the IPS policy being configured as Allow DNS Zone.