--- title: "Resolved issues" slug: "resolved-issues-8" tags: ["Release Notes", "NX 10.x", "Network Security", "Network Security (NX)"] updated: 2026-08-24T22:01:11Z published: 2026-08-24T22:01:11Z canonical: "docs.trellix.com/resolved-issues-8" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Resolved issues The following issues were resolved in the Network Security 10.0.0 release. | Tracking number | Summary | | --- | --- | | **COM-12986** | New logs could not be generated due to the Log Manager Create button being disabled and the progress showed "Archive being created". The issues are resolved. | | **COM-23960** | The physical disk serial number did not match the output of `show media disk`. This issue is resolved. | | **COM-29773** | Upgrading previously created certs under FireEye org name is not supported. | | **COM-29806** | Power supply failure alert notifications were created unnecessarily in the following models: NX 3500, NX 4500, NX 5500. This issue is resolved | | **COM-29863** | Apache has been upgraded to overcome the vulnerability described in IAVM 2022-A-0124. | | **COM-29874** | Vulnerabilities CVE-2022-22965, CVE-2022-22963, and CVE-2022-22950 are resolved. | | **COM-29002** | The *show log continuous* command was not generating the expected output. The issue is resolved. | | **COM-29377** | The Velocity Engine has been upgraded to address the Velocity Sandbox Bypass issue (CVE-2020-13936). | | **COM-29624** | Some appliances could not connect to HelixConnect. This issue is resolved. | | **COM-29702** | CEF logs did not have the cs6 field extension. This issue is resolved. | | **COM-30030** | Alert notifications and alert logs were delayed when many detections occurred simultaneously. This issue is resolved. | | **COM-30031** | The Apache vulnerability described in IAVM 2022-A-0230 has been addressed. | | **COM-30144** | The SMTP alerts using TLS failed to authenticate if the password contained a `#` character. This issue is resolved. | | **COM-30244** | mgmtd could not be recovered if a failure occurred. The issue is resolved. mgmtd can now be recovered by rebooting the system after a failure. | | **COM-30325** | SNMP settings used to reset to default values on reloading the site or logging out. The issue is resolved. | | **COM-30344** | TLS version 1.1 was not secure enough in compliance mode for CC-NDcPP 2022 certification. The issue is resolved. TLS is upgraded to version 1.2. | | **COM-30537** | CVE-2021-46848 vulnerability has been addressed. | | **COM-30604** | Delimiter between multiple SSH Allow users was not effective. The issue was resolved. | | **COM-30641** | The full file path was included in the "filename" field in the metadata that was sent to **cloud.fireeye.com**. This issue has been resolved. | | **COM-30743** | License update was producing the error message, "Internal error fetching licenses". The issue is resolved. | | **COM-30788** | You can now view datastreaming logs from the CLI using the `show datastreaming log` command. | | **COM-30894** | Issues of generating empty static reports have been fixed. | | **COM-30935** | SNMPv3 allowed the creation of a user with an invalid SNMP key. This issue is resolved. | | **COM-30950** | The original file names were being truncated in the malware analysis table during local and remote transfer. The issue is resolved. | | **COM-31007** | Apache has been upgraded to overcome the vulnerability described in CVE-2023-24998. | | **COM-31187** | Advanced URL Defense reported an error on the sensor appliance. The issue is resolved. | | **WEBMPS-21636** | Issues related to backup, restore and reset factory settings for IPS services are resolved. - IPS Custom Rules were missing from the Only Config backup. - when the `reset factory keep-all-config` CLI command was executed, IPS Policy Configuration, IPS Exception. Rules and IPS Custom Rules configuration were not retained. | | **WEBMPS-21803** | The NX 6500 appliance showed incorrect Warning and Critical values for Maximum bandwidth in both the CLI and the Web UI. The issues are resolved. | | **WEBMPS-24145** **WEBMPS-24841** | Security Content update failure did not trigger an SNMP trap. The issue is resolved. | | **WEBMPS-24321** | System Load and other services were generating false health alerts. The issues are resolved. | | **WEBMPS-24531** | ifName was not included in the interface-up / interface-down SNMP trap. This issue is resolved. | | **WEBMPS-24836** | The Network Security appliance could not cancel an active packet capture service. The issue is resolved. | | **WEBMPS-24884** | Source and destination IP addresses appeared interchanged on the Alert Details page and in XML and CSV files. The issue is resolved. | | **WEBMPS-25062** | An issue created by the escape characters '\/\/' in urllist.txt is resolved. | | **WEBMPS-25104** | Riskware alert severity was displayed as N/A on the Web UI Dashboard. This issue is resolved. | | **WEBMPS-25170** | The Network Security appliance in L3 mode was sending reset packets while the port-pairs were in TAP mode. This issue is resolved | | **WEBMPS-25195** | Inconsistencies in alerts from the Network Security appliance and Helix are resolved. | | **WEBMPS-25426** | 250-****STARTTLS response instead of 250-STARTTLS was not accepted on the Network Security appliance. This issue has been resolved. | | **WEBMPS-25615** | Proxy details were missing in the riskware alert notification. The issue is resolved. | | **WEBMPS-25679** | The Network Security appliance was receiving empty IP address on configuring drop out-interface. The issue is resolved. You need to execute *policymgr interface re-configure* CLI command after configuring any policymgr interface commands. | | **WEBMPS-25806** | A database corruption event created multiple issues on the Network Security 1500 appliance. These issues are resolved. | | **WEBMPS-26034** | Change in timezone was not being honoured by the Service Health Digest notification. This issue is resolved | | **WEBMPS-26238** | IPS custom rule validation failed for rules with UDP protocol and the TCP flags option. This issue is resolved. | | **WEBMPS-26249** | 'Backup Reserve/free spaces is too low' error was logged when generating a backup config+fedb even though disk space is enough to store more backups. This issue is resolved. | | **WEBMPS-26413** | The disk space under /var/root/tmp/sa_python was full. The issue is resolved. | | **WEBMPS-26418** | SSL connection was timing out due to delayed SYN ACK on the Network Security appliance. The issue is resolved. | | **WEBMPS-26426** | Inconsistency in ICAP blocking is resolved. | | **WEBMPS-26439** | Issues arising due to a TCP evasion technique are resolved. The evasion technique works by overlapping a TCP segment with a fake packet. | | **WEBUI-14724** | Naming a custom dashboard using non-ASCII and hyphen characters failed on the Web UI with the following error message: "Please enter a valid name". This issue is resolved. | | **WEBUI-14821** | When an IPS event was clicked on the Web UI, the page did not respond. IPS performance improvement has fixed this issue. |