--- title: "Resolved issues" slug: "resolved-issues-82" tags: ["Release Notes", "vIPS"] updated: 2026-09-01T18:26:52Z published: 2026-09-01T18:26:52Z canonical: "docs.trellix.com/resolved-issues-82" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Resolved issues The current release of the product resolves these issues. For a list of issues fixed in earlier releases, see the Release Notes for the specific release. For a list of current known issues, see:Trellix IPS 11.1 Known Issues [(KB96274)](https://kcm.trellix.com/corporate/index?page=content&id=KB96274). ### Resolved Manager software issues The following table lists the **medium-severity** Manager software issues: | Reference # | Resolution | | --- | --- | | NSPMGR-27357 | An attempt to import invalid licenses fails and the existing licenses disappear for Virtual Sensors in the Manager → → Setup → Licenses page. | | NSPMGR-27315 | Error occurs while creating or deleting HA pairs in the Manager, when Integration with Trellix Network Investigator is enabled. | | NSPMGR-27303 | Upgrade from software version 10.1.7.65 to 11.1.7.26 fails in Linux-based Manager. | | NSPMGR-27278 | Any change made in the Master Attack repository from IPS Central Manager or associated Managers does not reflect in the Policy → → Intrusion Prevention → Policy Types → IPS page. | | NSPMGR-27260 | Jumbo frame parsing and SSL decryption features get disabled in stack HA Sensors after upgrading to Sensor version 11.1.5.57. | | NSPMGR-27247 | Syslog messages show incorrect Interface names for member Sensors when NS9500 Sensors in stacks are configured with the Manager with syslog notification enabled. | | NSPMGR-27207 | Unable to export Sensor configuration using the Devices → → Devices → → Maintenance → Export Configuration page. | | NSPMGR-27192 | After configuring email server details in the Manager → → Setup → E-mail Server page and saving the changes, an error is displayed in the Manager on clicking the **Test Connection** button stating that the email server details are not saved. | | NSPMGR-27173 | Memory usage chart shows different values on loading and after refresh on the **Memory** tab in the Devices → → Devices → → Troubleshooting → Performance Charts page when **Decrypted Flow Pool** is selected as the metric. | | NSPMGR-20340 | After upgrading the stack Sensor software version from the **Device Manager** page, the Sensor fails to reboot automatically. | ### Resolved Sensor software issues The following table lists the **high-severity** Sensor software issues: | Reference # | Resolution | | --- | --- | | NSPSNSR-14946 | A process crash is observed when **Client Browser Detection** is enabled for Web Server - Denial-of-Service Protection feature and while parsing the jumbo frames. | The following table lists the **medium-severity** Sensor software issues: | Reference # | Resolution | | --- | --- | | NSPSNSR-15260 | Latency Alerts are observed with Sensor version 10.1.5.190 and later due to incorrect shared memory alignment in software. | | NSPSNSR-15126 | l7ae.console log file size becomes very big as the log rotation fails after upgrading the Sensor to version 11.1 or later. | | NSPSNSR-14448 | HTTP traffic on the non-standard destination ports is permitted despite the Quarantine Zone rules in the IPS policy being configured as **Allow DNS** Zone. | :