--- title: "Scenarios for MDR configuration" slug: "scenarios-for-mdr-configuration-2" tags: ["Product Usage", "IPS 11.1.x"] updated: 2026-11-19T12:28:23Z published: 2026-11-19T12:28:23Z canonical: "docs.trellix.com/scenarios-for-mdr-configuration-2" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Scenarios for MDR configuration ### Scenario 1 Two Managers are in an MDR pair, and you are adding the Sensor configuration information in Manager 1. **MDR Scenario 1**![MDR Scenario 1](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-7a628943-3d26-a7a8-6d66-7305cb15415e(7).png?sv=2026-02-06&spr=https&st=2026-11-20T09%3A12%3A29Z&se=2026-11-20T10%3A12%3A29Z&sr=c&sp=r&sig=3WUBd1O0CMghnn%2B%2FaYPCRq2snJqnX%2BbdXLH3AyUDEBY%3D) If connection A between Manager 1 and Manager 2 is over IPv4 network, and you are adding Sensor configuration in Manager 1, the communication between Manager 1 and Sensor (that is, connection B) should also be over IPv4 network. Similarly, if connection A between Manager 1 and Manager 2 is over IPv6 network, and you are adding Sensor configuration in Manager 1, the communication between Manager 1 and Sensor (that is, connection B) should also be over IPv6 network. If connection A between Manager 1 and Manager 2 is over both IPv4 and IPv6 networks, and you are adding Sensor configuration in Manager 1, the communication between Manager 1 and Sensor (that is, connection B) can be configured over either IPv4 or IPv6 network. ### Scenario 2 Suppose Manager 1 is standalone (not part of an MDR pair), and you want to add a peer Manager (that is, Manager 2) with Manager 1 to form an MDR pair. **MDR Scenario 2**![MDR Scenario 2](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-fb174622-1c1b-2cec-fbe9-28ab81bbbebb(7).png?sv=2026-02-06&spr=https&st=2026-11-20T09%3A12%3A29Z&se=2026-11-20T10%3A12%3A29Z&sr=c&sp=r&sig=3WUBd1O0CMghnn%2B%2FaYPCRq2snJqnX%2BbdXLH3AyUDEBY%3D) If the communication between Sensors and Manager 1 (that is, connection B and C) is over IPv4 network, the communication between Manager 1 and Manager 2 (that is, connection A) should also be configured for IPv4 network. Similarly, if the communication between Sensors and Manager 1 (that is, connection B and C) is over IPv6 network, the communication between Manager 1 and Manager 2 (that is, connection A) should also be configured for IPv6 network. If B and C support both IPv4 and IPv6 networks, A can be configured to support either IPv4 or IPv6 network.