--- title: "Sensor software and signature set upgrade using Manager 11.1" slug: "sensor-software-and-signature-set-upgrade-using-manager-11-1-1" tags: ["Install and Get Started", "IPS 11.1.x"] updated: 2026-11-19T12:53:55Z published: 2026-11-19T12:53:55Z canonical: "docs.trellix.com/sensor-software-and-signature-set-upgrade-using-manager-11-1-1" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Sensor software and signature set upgrade using Manager 11.1 **Prerequisite:** You have reviewed the notes on Sensor downtime window. See [Reviewing the upgrade considerations](/network-and-platform/docs/review-the-upgrade-considerations-for-sensors-2). **Steps:** 1. If you have not already done so, download the latest signature set in the Manager. In the Manager, go to **Manager** → **** → **Trellix IPS Protection Status**. Select **Signature Sets** tab. Then, select **Download Latest Signature Set**. See the Trellix Intrusion Prevention System Product Guide, for step-by-step information on how to download the signature set. For a list of currently supported protocols, see [KB61036](https://support.trellix.com/s/article/KB61036) at [Trellix Support Portal](https://support.trellix.com/s/). Do not push the signature set to your Sensors at this point; it will be sent with the Sensor software in step 8. > [!NOTE] > Note > > If you are using the Advanced Callback Detection feature, make sure you have downloaded the latest callback detectors to the Manager. See Trellix Intrusion Prevention System Product Guide for the details on downloading callback detectors. 2. If you had created Trellix IPS custom attacks in the previous version of the Manager, verify that those attacks are present in the Custom Attack Editor. 3. Download the most recent 11.1 Sensor software images from the Update Server onto the Manager. 1. To download the Sensor software version to the Manager, go to **Manager** → **** → **Trellix IPS Protection Status**. Select **Device Software** tab. The **Device Software** tab is displayed. Select **Download Device Software**. 2. Select the applicable Sensor software version from the **Software Available for Download** section and click **Download**. 4. To push the Sensor software to your Sensors, go to **Devices** → **** → **Global** → **Device Manager**. The **Device Manager** page is displayed. 5. Select the **Sensors** tab. From the list, select the required Sensor. The Manager provides an option to concurrently perform the software upgrade for multiple Sensors using same model and software version. > [!NOTE] > Note > > For selected Sensor, if the required software version is not downloaded in the Manager, an **Informational** dialog box is displayed. ![Sensor_software_and_signature_set_upgrade_using_Manager.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-cb6e15a9-4d7d-084a-1e19-c2fc50e54143(1).png?sv=2026-02-06&spr=https&st=2026-11-20T08%3A50%3A38Z&se=2026-11-20T09%3A50%3A38Z&sr=c&sp=r&sig=N95NIMXP5gesrI%2FBWNHPcCowKDelvJZQY1x%2F7hkI7bM%3D) 6. Select **Upgrade Device Software** from **Other Actions** drop-down. ![GUID-5DBE7597-087A-40D8-8503-DB47C096C689-low.jpg](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-6e72283c-22f2-ba54-f14b-aedcea61e01f(1).jpg?sv=2026-02-06&spr=https&st=2026-11-20T08%3A50%3A38Z&se=2026-11-20T09%3A50%3A38Z&sr=c&sp=r&sig=N95NIMXP5gesrI%2FBWNHPcCowKDelvJZQY1x%2F7hkI7bM%3D) The **Software Upgrade** dialog box is displayed. 7. Select the **New Software Version** to be downloaded to the Sensor from the drop-down. > [!NOTE] > Note > > You can only view the downloaded device software versions. 8. To automatically push the Sensor for reboot, enable **Reboot Automatically**. By default the this option is enabled. If required, it can be disabled. For NS-series Sensors, you must do a full reboot as hitless reboot is not supported when SSL decryption is enabled. 9. After reboot, you need to verify the status of Sensor through CLI and confirm if it displays **SIGFILE** or **NO_SIGFILE**. If the Sensor displays **NO_SIGFILE**, manually deploy sigfile to the Sensor using Manager. 10. Click the **Upgrade** to initiate the process. > [!NOTE] > Note > > This will push the signature set as well as the software to the Sensors. Signature set update could fail because of Snort custom attacks that contain unsupported PCRE constructs. In such cases, the *Incompatible custom attack* fault is raised in the **Faults** tab in **Manager** → **** → **Troubleshooting** → **Logs**. 11. Wait for the push to complete. This process takes at least 5 minutes. To know when the process is complete, log in to the Sensor and look for the following status by using the `downloadstatus` CLI command: - Last Upgrade Status: Good - Last Update Time: (Time should reflect when the push is complete) You will be prompted to reboot the Sensor upon completion of the Sensor software upgrade. 12. Once the reboot process is complete, verify that the Sensor's operational status is up; and that it comes up with the latest software version as well as latest signature set. To verify, go to **Devices** → **** → **Devices** → **** → **Summary**. Use the Performance Charts to verify the performance of the Sensors. This is to make sure the upgrade was successful. For information on how to check Sensor performance from Performance Charts, see Trellix Intrusion Prevention System Product Guide. > [!WARNING] > Important > > If you have a HA pair configured, both the Sensors forming the pair should be running on the same Sensor software version. See [Updating Sensor software in a failover pair](/network-and-platform/docs/update-sensor-software-in-a-ha-pair-2).