The new docs.trellix.com features a modernized UI and AI-powered conversational search. Content is currently available in English, with additional languages launching in early November 2026. We hope you enjoy the updated experience.

set fe-switch-hardware-hashing-method

Prev Next

This command is used to select the hashing method to distribute traffic through the Sensor.

Note the following:

  • In a HA pair, when you execute the command on the primary Sensor, the command is set on the secondary Sensor also.

  • Sensor reboot does not change settings for the hashing method.

Syntax:

set fe-switch-hardware-hashing-method <include_MPLS><exclude_MPLS>

Parameter

Description

include_MPLS

When the incoming traffic to the Sensor is MPLS (Multiprotocol Label Switching) traffic, select this method.

Note

This method will evenly distribute the MPLS traffic to the Sensor.

exclude_MPLS

This is enabled by default when the incoming traffic to the Sensor is non-MPLS traffic.

Sample output:

IntruDbg#> set fe-switch-hardware-hashing-method include_MPLS

include_MPLS : Rtag9 hashing algorithm to load balance traffic to trunk group(Id=10) is set

Applicable to:

NS9300 Sensors only