This command sets the admin status, operating mode, flowcontrol, and speed on the specified gigabit ethernet monitoring port. You can also use this command to set the specified Ethernet monitoring port to full-duplex or half-duplex.
It is not mandatory to use all the following parameters for this command.
Syntax:
set intfport id <port> <mediatype copper | optical> <adminstatus up | down> <duplex full|half> <flowcontrol gig | auto> <operating mode ifo | ifc | tap| span> <speed 100GBPS | 100MBPS | 100MBPS-auto | 10GBPS | 10GBPS-auto | 10MBPS | 1GBPS | 1GBPS-auto | 40GBPS> <fec disable | enable>
Parameter | Description |
|---|---|
<port> | A valid ethernet monitoring port on the Sensor Valid port numbers for NS-series Sensors (except NS3600) are: g0/1 | g0/2 | g1/1 | g1/2 | g1/3 | g1/4 | g1/5 | g1/6 | g1/7 | g1/8 | g1/9 | g1/10 | g1/11 | g1/12 | g2/1 | g2/2 | g2/3 | g2/4 | g2/5 | g2/6 | g2/7 | g2/8 | g2/9 | g2/10 | g2/11 | g2/12 | g3/1 | g3/2 | g3/3 | g3/4 | g3/5 | g3/6 | g3/7 | g3/8 Valid port-pairs for NS3600 Sensor are: 1-2 | 3-4 | 5-6 | 7-8 | 9-10 | 11-12 | 13-14 |
<mediatype> | Sets interface media type to Copper or Optical Fibre |
<adminstatus> | Enables or disables the interface port |
<duplex> | Sets this interface port to full or half duplex |
<operating mode> | Changes the operating mode in-line fail-open line fail-close, tap or span |
<speed> | Sets interface port speed to 100GBPS, 40GBPS, 10GBPS, 1GBPS, 100MBPS, 10MBPS, 10GBPS auto negotiate, 1GBPS auto negotiate, and 100MBPS auto negotiate
|
<fec> | Enables or disables forward error connection
|
Example:
set intfport id g2/2 speed 1GBPS-auto
Applicable to:
NS-series Sensors