--- title: "set portsettletime" slug: "set-portsettletime-3" tags: ["Product Usage", "IPS 11.1.x"] updated: 2026-11-19T12:29:52Z published: 2026-11-19T12:29:52Z canonical: "docs.trellix.com/set-portsettletime-3" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # set portsettletime The Sensor enables inline port pairs to act as a true 'wire'. This means that when one port in a pair is DOWN, its peer will also be brought DOWN, and vice versa — when one is UP, its peer will also be brought UP (contingent upon the status of the device to which it is connected). This is achieved via the `set portsettletime` command, which enables you to specify the "settle time" for the ports. When a port is enabled and is not UP for a duration equal to the port settling time, the port is considered DOWN. Since different switches take different amounts of time to negotiate, you must configure this value to a time period appropriate for your network. This value applies to all ports in the Sensor. Wire mode functionality is not enforced during the port settle time. **Syntax**: `set portsettletime <seconds>` | Parameter | Description | | --- | --- | | | Indicates the number of seconds between 0 and 300 | **Default Value**: The default value of is 30 (30 seconds). **Applicable to:** NS-series Sensors