--- title: "Set the L2 error drop threshold for specific devices" slug: "set-the-l2-error-drop-threshold-for-specific-devices" tags: ["Product Usage", "IPS 10.1.10"] updated: 2026-10-05T15:41:06Z published: 2026-10-05T15:41:06Z canonical: "docs.trellix.com/set-the-l2-error-drop-threshold-for-specific-devices" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Set the L2 error drop threshold for specific devices Follow this procedure for setting the L2 Error Drop threshold for a specific device within a domain. ## Task 1. Select **Devices** → **** → **Devices** → **** → **Setup** → **Performance Monitoring** → **Thresholds**. Thresholds area ![l2_error_drop_setting_sensor_name_node](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/GUID-5995B60D-96AD-49A6-85DA-8B44B97A53F3-low.png?sv=2026-02-06&spr=https&st=2026-11-22T14%3A04%3A49Z&se=2026-11-22T15%3A04%3A49Z&sr=c&sp=r&sig=zcLkdkZtp%2BiHODp093J7ajPWUqo4AiF10AY40Z74dIQ%3D) 2. Select **L2 Error Drop** in the drop down list against **Metric**. 3. Enter the required threshold in the **Threshold [counts/min]** column (this value should be higher than the value in the **Reset Threshold [counts/min]** column). 4. Select the **Generate Fault?** checkbox to generate fault. Deselect the **Generate Fault?** checkbox to disable generation of fault. 5. Click **Save** to save your settings. > [!NOTE] > Note > > Click **Defaults** to set the threshold settings to the default values. The threshold values can be changed only if the checkbox against **Inherit Settings?** is deselected.