Follow this procedure for setting Sensor throughput threshold for all devices within the admin domain.
Task
-
Click
Devices → <Admin Domain Name> → Global → Common Device Settings → Performance Monitoring → Thresholds.
Thresholds area 
- Select Device Throughput Usage in the drop down list against Metric.
- Enter the required threshold percentage in the Threshold [%] column (this value should be higher than the value in the Reset Threshold [%] column).
- Select Generate Fault? to generate fault.
-
Click
Save to save your settings.
Note
Click Defaults to set the threshold settings to the default values. "Under Usage" in the context of the throughput usage threshold is a 'falling threshold'. Alarm is generated when the throughput % drops below a certain value. This is helpful on very busy networks, where a certain amount of traffic is always expected to be seen. This type of alarm is a good indication that there is a communication problem on the network.
Note
By default High Usage setting of Sensor throughput usage threshold alarm is enabled and the rest are disabled at root domain.