Set the Sensor throughput threshold for devices within the admin domain

Prev Next

An alarm is generated when the throughput % drops below a certain value. This is helpful on very busy networks, where a certain amount of traffic is always expected to be seen. This type of alarm is a good indication that there is a communication problem on the network.

Note

By default, the High setting of the Sensor Throughput Usage threshold alarm is enabled and the rest are disabled at the parent (root) domain.

Follow this procedure for setting sensor throughput threshold for all devices within the admin domain.

  1. From the Performance Monitoring node, select Devices > <admin domain name> > Global > Common Device Settings > Performance Monitoring > Thresholds.

  2. Select the Medium, High, or Low row in Sensor Throughput Usage and enter the required threshold percentage in the Threshold field.

    This value should be higher than the value in the Reset Threshold field.

  3. (Optional) Select the Generate Fault checkbox.

    Faults are visible in the logs.  

  4. Click Save.