Follow this procedure for setting Sensor throughput threshold for all devices within the admin domain.
Click Devices → <Admin Domain Name> → Global → Common Device Settings → Performance Monitoring → Thresholds.
Thresholds area.png)
Select Device Throughput Usage in the drop down list against Metric.
Enter the required threshold percentage in the Threshold [%] column (this value should be higher than the value in the Reset Threshold [%] column).
Select Generate Fault? to generate fault.
Click Save to save your settings.
Note
Click Defaults to set the threshold settings to the default values. "Under Usage" in the context of the throughput usage threshold is a 'falling threshold'. Alarm is generated when the throughput % drops below a certain value. This is helpful on very busy networks, where a certain amount of traffic is always expected to be seen. This type of alarm is a good indication that there is a communication problem on the network.
Note
By default High Usage setting of Sensor throughput usage threshold alarm is enabled and the rest are disabled at root domain.