The new docs.trellix.com features a modernized UI and AI-powered conversational search. Content is currently available in English, with additional languages expected in November 2026. We hope you enjoy the updated experience.

Setting the Sensor throughput threshold for specific devices

Prev Next

A fault is generated when the throughput % drops below a certain value. This is helpful on very busy networks, where a certain amount of traffic is always expected to be seen. This type of fault is a good indication that there is a communication problem on the network.

Follow this procedure for setting the Sensor throughput threshold for a specific device within a domain.

  1. From the Performance Monitoring node, select Devices > <admin domain name> > Devices > <device name> > Setup > Performance Monitoring > Thresholds.

    The Metrics tab opens by default.

  2. Select the High, Medium, or Low row in Sensor Throughput Usage and enter the required threshold percentage in the Threshold field.

    This value should be higher than the value in the Reset Threshold field.

  3. (Optional) Select the Generate Fault checkbox.

  4. Click Save.