NS-series Sensor port fail-open behavior
Each Sensor model is shipped with documentation on how to set up the Sensor and configure it to communicate with the Manager. This documentation consists of model-specific product guides and quick start guides. These documents provide detailed installation, configuration and cabling instructions for your Sensor.You may need special equipment depending on your deployment strategy. Certain Sensor models have Fast Ethernet (FE) ports. Each FE port requires a Trellix IPS dongles for In-line Fail-closed mode. Dongles are included with FE-port Sensors. Gigabit Ethernet (GE) port Sensors require the optional Gigabit fail-open bypass kit (Optical Single-mode, Optical Multimode, or Copper), sold separately, for in-line fail-open mode. Refer to the appropriate fail-open kit guides for more details.
The following table shows the monitoring port types for each Sensor model.
| NS-series Sensor | Monitoring port type | Default port operation mode | Internal Fail-open ports | External Active Fail-open Kit | External Passive Fail-open Kit |
|---|---|---|---|---|---|
| NS9500 | GE ports | Inline fail-open | Supports built-in internal Fail-open on the following ports:
|
Supports Active Fail-open on the following ports:
|
Not supported |
| NS9300 | GE ports | Inline fail-open | Supports built-in internal Fail-open on the following ports:
|
Supports Active Fail-open on the following ports:
|
Not supported |
| NS9200 | GE ports | Inline fail-open | Supports built-in internal Fail-open on the following ports:
|
Supports Active Fail-open on the following ports:
|
Not supported |
| NS9100 | GE ports | Inline fail-open | Supports built-in internal Fail-open on the following ports:
|
Supports Active Fail-open on the following ports:
|
Not supported |
| NS7500 | GE ports | Inline fail-open | Supports built-in internal Fail-open on the following ports:
|
Supports Active Fail-open on the following ports:
|
Supported on G0/1 and G0/2 interface only. |
| NS7350 / NS7250 / NS7150 | GE ports | Inline fail-open | Supports built-in internal Fail-open on the following ports:
|
Supports Active Fail-open on the following ports:
|
Supported on G0/1 and G0/2 interface only. |
| NS7300 / NS7200 / NS7100 | GE ports | Inline fail-open | Supports built-in internal Fail-open on the following ports:
|
Supports Active Fail-open on the following ports:
|
Supported on G0/1 and G0/2 interface only. |
| NS5200 / NS5100 | GE ports | Inline fail-open | Supports built-in internal Fail-open on the following ports:
|
Supports Active Fail-open on the following ports:
|
Supported on G0/1-2, G1/1-2 to G1/11-12 interface ports. |
| NS3500 | GE ports | Inline fail-open | Supports built-in internal Fail-open on the following ports:
|
Not supported | Not supported |
| NS3200/NS3100 | GE ports | Inline fail-open | Supports built-in internal Fail-open on the following ports:
|
Supports Active Fail-open on the following ports:
|
Not supported |
The NS-series Sensors support network interface modules in the G1 and G2 slots. Based on the type of modules, the ports have fail-open behavior as briefed below.
| I/O modules | Monitoring port type | Default port operation mode | Internal (Fail-open built-in) | External AFO Kit | External PFO Kit |
|---|---|---|---|---|---|
| 2-port (QSFP+) 100 GigE | GE ports | Inline fail-closed | No | Required for active fail-open | Not supported |
| 4-port (QSFP+) 40 GigE | |||||
| 2-port (QSFP+) 40 GigE | |||||
| 2-port 100/40 GigE SR MTP/MPO with Internal fail-open | Inline-fail open | Yes |
| I/O modules | Monitoring port type | Default port operation mode | Internal (Fail-open built-in) | External AFO Kit | External PFO Kit |
|---|---|---|---|---|---|
| 4-port (QSFP+) 40 GigE | GE ports | Inline fail-closed | No | Required for active fail-open | Not supported |
| 2-port (QSFP+) 40 GigE |
| I/O modules | Monitoring port type | Default port operation mode | Internal (Fail-open built-in) | External AFO Kit | External PFO Kit |
|---|---|---|---|---|---|
| 8-port (SFP+/SFP) 10/1 GigE | GE ports | Inline fail-closed | No | Required for active fail-open | Not supported |
| 4-port RJ-45 10 GigE with internal fail-open | GE ports | Inline fail-open | Yes (All port pairs) | Required for active fail-open | Not supported |
| 6-port RJ-45 1 GigE with internal fail-open | |||||
| 4-port SFP+ 1/10 GigE SR Optical 50 micron with internal fail-open | |||||
| 4-port SFP+ 1/10 GigE SR Optical 62.5 micron with internal fail-open | |||||
| 4-port SFP+ 1/10 GigE LR Optical with internal fail-open |
VM-IPS Sensor port fail-open behavior
| Virtual IPS Sensor | Monitoring port type | Default port operation mode | Internal (Fail-open built-in) | External Active Fail-open Kit | External Passive Fail-open Kit |
|---|---|---|---|---|---|
| IPS-VM600 | GE ports | Inline fail-closed | No | Required for active fail-open | Not supported |
Note
External AFO kit is applicable to scenarios where the Virtual Sensor is between two physical network devices. For inline inspection of traffic to virtual machines, only fail-closed mode is applicable.
M-series Sensor port fail-open behavior
| M-series Sensor | Monitoring port type | Default port operation mode | Internal Fail-open ports | External Active Fail-open Kit | External Passive Fail-open Kit |
|---|---|---|---|---|---|
| M8000 | GE ports | Inline fail-closed | None | Supports Active Fail-open on the following ports:
|
Supports Passive Fail-open on the following ports:
|
| M6050 | GE ports | Inline fail-closed | None | Supports Active Fail-open on the following ports:
|
Supports Passive Fail-open on the following ports:
|
| M4050 | GE ports | Inline fail-closed | None | Supports Active Fail-open on the following ports:
|
Supports Passive Fail-open on the following ports:
|
| M3050 | GE ports | Inline fail-closed | None | Supports Active Fail-open on the following ports:
|
Supports Passive Fail-open on the following ports:
|
| M2950 | GE ports | Inline fail-closed | Supports internal Fail-open on the following ports:
|
Supports Active Fail-open on the following ports:
|
Supports Passive Fail-open on the following ports:
|
| M2850 | GE ports | Inline fail-open | Supports internal Fail-open on the following ports:
|
Supports Active Fail-open on the following ports:
|
Supports Passive Fail-open on the following ports:
|
| M1450 | GE ports | Inline fail-open | Supports internal Fail-open on the following ports:
|
Not supported | Not supported |
| M1250 | GE ports | Inline fail-open | Supports internal Fail-open on the following ports:
|
Not supported | Not supported |