--- title: "Setting up the Sensor" slug: "setting-up-the-sensor-14" tags: ["Product Usage", "IPS 11.1.x"] updated: 2026-11-19T12:31:15Z published: 2026-11-19T12:31:15Z canonical: "docs.trellix.com/setting-up-the-sensor-14" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Setting up the Sensor ### NS-series Sensor port fail-open behavior Each Sensor model is shipped with quick-start guides on how to set up the Sensor and configure it to communicate with the Manager, or a content sheet that provides access to model-specific hardware guide documentation. These documents provide detailed installation, configuration and cabling instructions for your Sensor. The following table shows the monitoring port types for each Sensor model. **NS-series Sensors: Port fail-open behavior** | NS-series Sensor | Monitoring port type | Default port operation mode | Internal Fail-open ports | External Active Fail-open Kit | External Passive Fail-open Kit | | --- | --- | --- | --- | --- | --- | | NS9600 | GE ports | Inline fail-open - on I/O pluggable modules with built-in fail-open Inline fail-close - on G0 Inline fail-close - on G1/G2 for 4-Port 100/40 Gigabit SR MTP/MPO | Supports built-in internal Fail-open on the following ports: - G1,G2,G3(I/O: 6x10/1G Cu; 8x10G/1G Fi; 4x100/40g BiDi, LR4, and SR with built-in fail-open) | Supports Active Fail-open on the following ports: - Built-in G0 slot - All in I/O Modules supported in G1,G2, G3 Group Slots | Not supported | | NS9500 | GE ports | Inline fail-open | Supports built-in internal Fail-open on the following ports: - G1,G2(I/O: 6x1G Cu; 4x10G Cu; 4x10G/1G Fi, 2x100G/40G Fi) - RJ45 10G (G3/1-2 to G3/3-4) | Supports Active Fail-open on the following ports: - All in I/O Modules supported in G1,G2 Group Slots - RJ45 10G (G3/1-2 to G3/3-4) - QSFP+ 40G(G0/1-2) - QSFP28 100 GigE | Not supported | | NS9300 | GE ports | Inline fail-open | Supports built-in internal Fail-open on the following ports: - G1,G2,G5,G6(I/O: 6x1G Cu; 4x10G Cu; 4x10G/1G Fi) - RJ45 1G (G3/1-2 to G3/7-8) - RJ45 1G (G7/1-2 to G7/7-8) | Supports Active Fail-open on the following ports: - All in I/O Modules supported in G1,G2,G5,G6 Group Slots - RJ45 1G (G3/1-2 to G3/7-8) - RJ45 1G (G7/1-2 to G7/7-8) | Not supported | | NS9200 | GE ports | Inline fail-open | Supports built-in internal Fail-open on the following ports: - G1,G2(I/O: 6x1G Cu; 4x10G Cu; 4x10G/1G Fi) - RJ45 1G (G3/1-2 to G3/7-8) | Supports Active Fail-open on the following ports: - All in I/O Modules supported in G1,G2 Group Slots - RJ45 1G (G3/1-2 to G3/7-8) - QSFP+ 40G(G0/1-2) | Not supported | | NS9100 | GE ports | Inline fail-open | Supports built-in internal Fail-open on the following ports: - G1,G2(I/O: 6x1G Cu; 4x10G Cu; 4x10G/1G Fi) - RJ45 1G (G3/1-2 to G3/7-8) | Supports Active Fail-open on the following ports: - All in I/O Modules supported in G1,G2 Group Slots - RJ45 1G (G3/1-2 to G3/7-8) - SFP+ 10G/1G (G0/1-2) | Not supported | | NS7600 | GE ports | In-line fail-open on pluggable I/O modules In-line fail-close on built-in G0 | Supports built-in internal Fail-open on the following ports: - G1,G2,G3 (I/O: 6x10/1G Cu; 8x10G/1G Fi) | Supports Active Fail-open on the following ports: - Built-in G0 slot - All in I/O Modules supported in G1,G2, G3 Group Slots | Not supported | | NS7500 | GE ports | Inline fail-open | Supports built-in internal Fail-open on the following ports: - G1,G2(I/O: 6x1G Cu; 4x10G Cu; 4x10G/1G Fi) - RJ45 1G (G3/1-2 to G3/7-8) | Supports Active Fail-open on the following ports: - All in I/O Modules supported in G1,G2 Group Slots - RJ45 1G (G3/1-2 to G3/7-8) - SFP+ 10G/1G(G0/1-2) | Supported on G0/1 and G0/2 interface only. | | NS7350 / NS7250 / NS7150 | GE ports | Inline fail-open | Supports built-in internal Fail-open on the following ports: - G1,G2(I/O: 6x1G Cu; 4x10G Cu; 4x10G/1G Fi) - RJ45 1G (G3/1-2 to G3/7-8) | Supports Active Fail-open on the following ports: - All in I/O Modules supported in G1,G2 Group Slots - RJ45 1G (G3/1-2 to G3/7-8) - SFP+ 10G/1G(G0/1-2) | Supported on G0/1 and G0/2 interface only. | | NS7300 / NS7200 / NS7100 | GE ports | Inline fail-open | Supports built-in internal Fail-open on the following ports: - G1,G2(I/O: 6x1G Cu; 4x10G Cu; 4x10G/1G Fi) - RJ45 1G (G3/1-2 to G3/7-8) | Supports Active Fail-open on the following ports: - All in I/O Modules supported in G1,G2 Group Slots - RJ45 1G (G3/1-2 to G3/7-8) - SFP+ 10G/1G (G0/1-2) | Supported on G0/1 and G0/2 interface only. | | NS5200 / NS5100 | GE ports | Inline fail-open | Supports built-in internal Fail-open on the following ports: - RJ45 1G (G2/1-2 to G2/7-8) | Supports Active Fail-open on the following ports: - SFP+ 10/SFP 1G (G0/1-2) - SFP 1G Cu/Fi(G1/1-2 to G1/11-12) - RJ45 1G(G2/1-2 to G2/7-8) | Supported on G0/1-2, G1/1-2 to G1/11-12 interface ports. | | NS3600 | GE ports | Inline fail-open | Supports built-in internal Fail-open on the following ports: - RJ45 1 Gbps/100 Mbps/10 Mbps (1-4, 7-14) - Fiber ports 10 Gbps/1 Gbps (11-14) | Supports Active Fail-open on the following ports: - RJ45 1 Gbps/100 Mbps/10 Mbps (1-4, 7-14) - Fiber ports 10 Gbps/1 Gbps (5-6, 11-14) | Not supported | | NS3500 | GE ports | Inline fail-open | Supports built-in internal Fail-open on the following ports: - RJ45 1G(1-2 and 3-4) | Supported - RJ45 1G(1-2 and 3-4) | Not supported | | NS3200/NS3100 | GE ports | Inline fail-open | Supports built-in internal Fail-open on the following ports: - RJ45 1G(1-2 to 7-8) | Supports Active Fail-open on the following ports: - RJ45 1G(1-2 to 7-8) | Not supported | The NS-series Sensors support network interface modules in the G1, G2 and G3 slots. Based on the type of modules, the ports have fail-open behavior as briefed below. **Interface modules: Only NS9600 Sensors (G1, G2, and G3 ports)** | I/O modules | Monitoring port type | Default port operation mode | Internal (Fail-open built-in) | External AFO Kit | External PFO Kit | | --- | --- | --- | --- | --- | --- | | 4-port 100/40 GigE SR MTP/MPO* | GE ports | Inline fail-close | No | Required for active fail-open | Not supported | | 4-port 100/40 GigE SR MTP/MPO with internal fail open* | GE ports | Inline fail-open | Yes (All port pairs) | Required for active fail-open | Not supported | | 4-port 40 GigE LR4 with internal fail open* | | 4-port 100 GigE LR4 with internal fail open* | | 4-port 100/40 GigE BiDi with internal fail open* | | 6-port RJ45 10/1 GigE with internal fail-open | | 8-port 10/1 GigE SM and MM with internal fail-open | | *These network interface modules are supported only in G1 and G2 ports of NS9600 Sensor. | > [!WARNING] > Important > > The 4-port 100/40 Gigabit with internal fail open interface modules (that is, 100/40 Gigabit SR MTP/MPO, 40 Gigabit LR4, 100 Gigabit LR4, and 100/40 Gigabit BiDi) are supported in NS9600 Sensors running on 11.1 Update 8 version or later. **Interface modules: Only for NS9500 Sensor (G1 and G2 slot ports)** | I/O modules | Monitoring port type | Default port operation mode | Internal (Fail-open built-in) | External AFO Kit | External PFO Kit | | --- | --- | --- | --- | --- | --- | | 2-port (QSFP28) 100 GigE | GE ports | Inline fail-closed | No | Required for active fail-open | Not supported | | 4-port (QSFP+) 40 GigE | | 2-port (QSFP+) 40 GigE | | 2-port 100/40 GigE SR MTP/MPO with Internal fail-open | Inline-fail open | Yes | **Interface modules: Only NS9x00 Sensors (G1 and G2 slot ports)** | I/O modules | Monitoring port type | Default port operation mode | Internal (Fail-open built-in) | External AFO Kit | External PFO Kit | | --- | --- | --- | --- | --- | --- | | 4-port (QSFP+) 40 GigE | GE ports | Inline fail-closed | No | Required for active fail-open | Not supported | | 2-port (QSFP+) 40 GigE | **Interface modules: Only NS7600 Sensors (G1, G2, and G3 ports)** | I/O modules | Monitoring port type | Default port operation mode | Internal (Fail-open built-in) | External AFO Kit | External PFO Kit | | --- | --- | --- | --- | --- | --- | | 6-port RJ45 10/1 GigE with internal fail-open | GE ports | Inline fail-open | Yes (All port pairs) | Required for active fail-open | Not supported | | 8-port 10/1 GigE SM and MM with internal fail-open | **Interface modules: NS9x00, NS7500, NS7x50, and NS7x00 Sensors (G1 and G2 ports)** | I/O modules | Monitoring port type | Default port operation mode | Internal (Fail-open built-in) | External AFO Kit | External PFO Kit | | --- | --- | --- | --- | --- | --- | | 8-port (SFP+/SFP) 10/1 GigE | GE ports | Inline fail-closed | No | Required for active fail-open | Not supported | | 4-port RJ-45 10 GigE with internal fail-open | GE ports | Inline fail-open | Yes (All port pairs) | Required for active fail-open | Not supported | | 6-port RJ-45 1 GigE with internal fail-open | | 4-port SFP+ 1/10 GigE SR Optical 50 micron with internal fail-open | | 4-port SFP+ 1/10 GigE SR Optical 62.5 micron with internal fail-open | | 4-port SFP+ 1/10 GigE LR Optical with internal fail-open | **Interface modules: Only NS3600 Sensor (Ports 11-14)** | I/O modules | Monitoring port type | Default port operation mode | Internal (Fail-open built-in) | External AFO Kit | External PFO Kit | | --- | --- | --- | --- | --- | --- | | 4-port RJ-45 1 Gbps/100 Mbps/10 Mbps with internal fail-open | GE ports | Inline fail-open | Yes (All port pairs) | Required for active fail-open | Not supported | | 4-port 10/1 GigE MM 50/62.5 μm with internal fail-open | ### VM-IPS Sensor port fail-open behavior | Virtual IPS Sensor | Monitoring port type | Default port operation mode | Internal (Fail-open built-in) | External Active Fail-open Kit | External Passive Fail-open Kit | | --- | --- | --- | --- | --- | --- | | IPS-VM600 and IPS-VM5000 | GE ports | Inline fail-closed | No | Required for active fail-open | Not supported | > [!NOTE] > Note > > External AFO kit is applicable to scenarios where the Virtual Sensor is between two physical network devices. For inline inspection of traffic to virtual machines, only fail-closed mode is applicable.