NS-series Sensor port fail-open behavior

Each Sensor model is shipped with quick-start guides on how to set up the Sensor and configure it to communicate with the Manager, or a content sheet that provides access to model-specific hardware guide documentation. These documents provide detailed installation, configuration and cabling instructions for your Sensor.

The following table shows the monitoring port types for each Sensor model.

NS-series Sensors: Port fail-open behavior

NS-series Sensor

Monitoring port type

Default port operation mode

Internal Fail-open ports

External Active Fail-open Kit

External Passive Fail-open Kit

NS9600

GE ports

Inline fail-open - on I/O pluggable modules with built-in fail-open

Inline fail-close - on G0

Inline fail-close - on G1/G2 for 4-Port 100/40 Gigabit SR MTP/MPO

Supports built-in internal Fail-open on the following ports:

  • G1,G2,G3(I/O: 6x10/1G Cu; 8x10G/1G Fi; 4x100/40g BiDi, LR4, and SR with built-in fail-open)

Supports Active Fail-open on the following ports:

  • Built-in G0 slot

  • All in I/O Modules supported in G1,G2, G3 Group Slots

Not supported

NS9500

GE ports

Inline fail-open

Supports built-in internal Fail-open on the following ports:

  • G1,G2(I/O: 6x1G Cu; 4x10G Cu; 4x10G/1G Fi, 2x100G/40G Fi)

  • RJ45 10G (G3/1-2 to G3/3-4)

Supports Active Fail-open on the following ports:

  • All in I/O Modules supported in G1,G2 Group Slots

  • RJ45 10G (G3/1-2 to G3/3-4)

  • QSFP+ 40G(G0/1-2)

  • QSFP28 100 GigE

Not supported

NS9300

GE ports

Inline fail-open

Supports built-in internal Fail-open on the following ports:

  • G1,G2,G5,G6(I/O: 6x1G Cu; 4x10G Cu; 4x10G/1G Fi)

  • RJ45 1G (G3/1-2 to G3/7-8)

  • RJ45 1G (G7/1-2 to G7/7-8)

Supports Active Fail-open on the following ports:

  • All in I/O Modules supported in G1,G2,G5,G6 Group Slots

  • RJ45 1G (G3/1-2 to G3/7-8)

  • RJ45 1G (G7/1-2 to G7/7-8)

Not supported

NS9200

GE ports

Inline fail-open

Supports built-in internal Fail-open on the following ports:

  • G1,G2(I/O: 6x1G Cu; 4x10G Cu; 4x10G/1G Fi)

  • RJ45 1G (G3/1-2 to G3/7-8)

Supports Active Fail-open on the following ports:

  • All in I/O Modules supported in G1,G2 Group Slots

  • RJ45 1G (G3/1-2 to G3/7-8)

  • QSFP+ 40G(G0/1-2)

Not supported

NS9100

GE ports

Inline fail-open

Supports built-in internal Fail-open on the following ports:

  • G1,G2(I/O: 6x1G Cu; 4x10G Cu; 4x10G/1G Fi)

  • RJ45 1G (G3/1-2 to G3/7-8)

Supports Active Fail-open on the following ports:

  • All in I/O Modules supported in G1,G2 Group Slots

  • RJ45 1G (G3/1-2 to G3/7-8)

  • SFP+ 10G/1G (G0/1-2)

Not supported

NS7600

GE ports

In-line fail-open on pluggable I/O modules

In-line fail-close on built-in G0

Supports built-in internal Fail-open on the following ports:

  • G1,G2,G3 (I/O: 6x10/1G Cu; 8x10G/1G Fi)

Supports Active Fail-open on the following ports:

  • Built-in G0 slot

  • All in I/O Modules supported in G1,G2, G3 Group Slots

Not supported

NS7500

GE ports

Inline fail-open

Supports built-in internal Fail-open on the following ports:

  • G1,G2(I/O: 6x1G Cu; 4x10G Cu; 4x10G/1G Fi)

  • RJ45 1G (G3/1-2 to G3/7-8)

Supports Active Fail-open on the following ports:

  • All in I/O Modules supported in G1,G2 Group Slots

  • RJ45 1G (G3/1-2 to G3/7-8)

  • SFP+ 10G/1G(G0/1-2)

Supported on G0/1 and G0/2 interface only.

NS7350 / NS7250 / NS7150

GE ports

Inline fail-open

Supports built-in internal Fail-open on the following ports:

  • G1,G2(I/O: 6x1G Cu; 4x10G Cu; 4x10G/1G Fi)

  • RJ45 1G (G3/1-2 to G3/7-8)

Supports Active Fail-open on the following ports:

  • All in I/O Modules supported in G1,G2 Group Slots

  • RJ45 1G (G3/1-2 to G3/7-8)

  • SFP+ 10G/1G(G0/1-2)

Supported on G0/1 and G0/2 interface only.

NS7300 / NS7200 / NS7100

GE ports

Inline fail-open

Supports built-in internal Fail-open on the following ports:

  • G1,G2(I/O: 6x1G Cu; 4x10G Cu; 4x10G/1G Fi)

  • RJ45 1G (G3/1-2 to G3/7-8)

Supports Active Fail-open on the following ports:

  • All in I/O Modules supported in G1,G2 Group Slots

  • RJ45 1G (G3/1-2 to G3/7-8)

  • SFP+ 10G/1G (G0/1-2)

Supported on G0/1 and G0/2 interface only.

NS5200 / NS5100

GE ports

Inline fail-open

Supports built-in internal Fail-open on the following ports:

  • RJ45 1G (G2/1-2 to G2/7-8)

Supports Active Fail-open on the following ports:

  • SFP+ 10/SFP 1G (G0/1-2)

  • SFP 1G Cu/Fi(G1/1-2 to G1/11-12)

  • RJ45 1G(G2/1-2 to G2/7-8)

Supported on G0/1-2, G1/1-2 to G1/11-12 interface ports.

NS3600

GE ports

Inline fail-open

Supports built-in internal Fail-open on the following ports:

  • RJ45 1 Gbps/100 Mbps/10 Mbps (1-4, 7-14)

  • Fiber ports 10 Gbps/1 Gbps (11-14)

Supports Active Fail-open on the following ports:

  • RJ45 1 Gbps/100 Mbps/10 Mbps (1-4, 7-14)

  • Fiber ports 10 Gbps/1 Gbps (5-6, 11-14)

Not supported

NS3500

GE ports

Inline fail-open

Supports built-in internal Fail-open on the following ports:

  • RJ45 1G(1-2 and 3-4)

Supported

  • RJ45 1G(1-2 and 3-4)

Not supported

NS3200/NS3100

GE ports

Inline fail-open

Supports built-in internal Fail-open on the following ports:

  • RJ45 1G(1-2 to 7-8)

Supports Active Fail-open on the following ports:

  • RJ45 1G(1-2 to 7-8)

Not supported



The NS-series Sensors support network interface modules in the G1, G2 and G3 slots. Based on the type of modules, the ports have fail-open behavior as briefed below.

Interface modules: Only NS9600 Sensors (G1, G2, and G3 ports)

I/O modules

Monitoring port type

Default port operation mode

Internal (Fail-open built-in)

External AFO Kit

External PFO Kit

4-port 100/40 GigE SR MTP/MPO*

GE ports

Inline fail-close

No

Required for active fail-open

Not supported

4-port 100/40 GigE SR MTP/MPO with internal fail open*

GE ports

Inline fail-open

Yes (All port pairs)

Required for active fail-open

Not supported

4-port 40 GigE LR4 with internal fail open*

4-port 100 GigE LR4 with internal fail open*

4-port 100/40 GigE BiDi with internal fail open*

6-port RJ45 10/1 GigE with internal fail-open

8-port 10/1 GigE SM and MM with internal fail-open

*These network interface modules are supported only in G1 and G2 ports of NS9600 Sensor.



Important

The 4-port 100/40 Gigabit with internal fail open interface modules (that is, 100/40 Gigabit SR MTP/MPO, 40 Gigabit LR4, 100 Gigabit LR4, and 100/40 Gigabit BiDi) are supported in NS9600 Sensors running on 11.1 Update 8 version or later.

Interface modules: Only for NS9500 Sensor (G1 and G2 slot ports)

I/O modules

Monitoring port type

Default port operation mode

Internal (Fail-open built-in)

External AFO Kit

External PFO Kit

2-port (QSFP28) 100 GigE

GE ports

Inline fail-closed

No

Required for active fail-open

Not supported

4-port (QSFP+) 40 GigE

2-port (QSFP+) 40 GigE

2-port 100/40 GigE SR MTP/MPO with Internal fail-open

Inline-fail open

Yes



Interface modules: Only NS9x00 Sensors (G1 and G2 slot ports)

I/O modules

Monitoring port type

Default port operation mode

Internal (Fail-open built-in)

External AFO Kit

External PFO Kit

4-port (QSFP+) 40 GigE

GE ports

Inline fail-closed

No

Required for active fail-open

Not supported

2-port (QSFP+) 40 GigE



Interface modules: Only NS7600 Sensors (G1, G2, and G3 ports)

I/O modules

Monitoring port type

Default port operation mode

Internal (Fail-open built-in)

External AFO Kit

External PFO Kit

6-port RJ45 10/1 GigE with internal fail-open

GE ports

Inline fail-open

Yes (All port pairs)

Required for active fail-open

Not supported

8-port 10/1 GigE SM and MM with internal fail-open



Interface modules: NS9x00, NS7500, NS7x50, and NS7x00 Sensors (G1 and G2 ports)

I/O modules

Monitoring port type

Default port operation mode

Internal (Fail-open built-in)

External AFO Kit

External PFO Kit

8-port (SFP+/SFP) 10/1 GigE

GE ports

Inline fail-closed

No

Required for active fail-open

Not supported

4-port RJ-45 10 GigE with internal fail-open

GE ports

Inline fail-open

Yes (All port pairs)

Required for active fail-open

Not supported

6-port RJ-45 1 GigE with internal fail-open

4-port SFP+ 1/10 GigE SR Optical 50 micron with internal fail-open

4-port SFP+ 1/10 GigE SR Optical 62.5 micron with internal fail-open

4-port SFP+ 1/10 GigE LR Optical with internal fail-open



Interface modules: Only NS3600 Sensor (Ports 11-14)

I/O modules

Monitoring port type

Default port operation mode

Internal (Fail-open built-in)

External AFO Kit

External PFO Kit

4-port RJ-45 1 Gbps/100 Mbps/10 Mbps with internal fail-open

GE ports

Inline fail-open

Yes (All port pairs)

Required for active fail-open

Not supported

4-port 10/1 GigE MM 50/62.5 μm with internal fail-open



VM-IPS Sensor port fail-open behavior

Virtual IPS Sensor

Monitoring port type

Default port operation mode

Internal (Fail-open built-in)

External Active Fail-open Kit

External Passive Fail-open Kit

IPS-VM600 and IPS-VM5000

GE ports

Inline fail-closed

No

Required for active fail-open

Not supported

Note

External AFO kit is applicable to scenarios where the Virtual Sensor is between two physical network devices. For inline inspection of traffic to virtual machines, only fail-closed mode is applicable.