This command displays all the current configuration settings on the Sensor such as model, installed software version, IP address, and Manager details.
This command has no parameters.
Syntax:
show
Information displayed by the show command includes the following:
[Sensor Info]
- Date
- System Uptime
- System Type
- System Mode
Note
System mode is displayed only for the NS9500 Sensors.
- Software Version
- MGMT Ethernet Port
- System serial number (displays the primary, secondary and master/system serial numbers separately in case of NS9300)
[Sensor Network Config]
- IP Address
- Netmask
- Default Gateway
- Default TFTP server
[Manager Config]
- Manager IP addr
- Install TCP Port
- Alert TCP Port
[Peer Manager Config]
- Manager IP addr
- Install TCP Port
- Alert TCP Port
Sample Output:
- For Sensor, the output is as shown below:
intruShell@john> show
[Sensor Info]
System Name : NS7350
Date : 2/6/2015 - 9:23:18 UTC
System Uptime : 6 days 23 hrs 10 min 13 secs
System Type : NS7350
System Mode : Stack
Serial Number : J021834009
Software Version : 9.2.5.98
Hardware Version : 1.30
MGMT Ethernet port : auto negotiated
MGMT port Link Status : link up
[Sensor Network Config]
IP Address : 10.1.1.1
Netmask : 255.255.255.0
Default Gateway : 10.1.1.2
SSH Remote Logins : enabled
[Manager Config]
Manager IP addr : 10.1.1.3 (primary intf)
Install TCP Port : 8506
Alert TCP Port : 8507
Logging TCP Port : 8508
- For NS9300 Sensor, the output is as shown below:
intruShell@KAM9300> show
[Sensor Info]
System Name : KAM9300
Date : 1/28/2015 - 8:34:53 UTC
System Uptime : 6 days 22 hrs 03 min 43 secs
System Type : IPS-NS9300
System Serial Number : J073350027
NS9300 P Serial Number : J071328008
NS9300 S Serial Number : J064227B70
Software Version : 9.1.5.71
Hardware Version : 1.10
MGMT Ethernet port : auto negotiated
MGMT port Link Status : link up
[Sensor Network Config]
IP Address : 1.1.1.1
Netmask : 255.255.255.0
Default Gateway : 1.1.1.5
Default SCPserver : 1.2.3.4
SSH Remote Logins : enabled
[Manager Config]
Manager IP addr : 1.1.1.2 (primary intf)
Install TCP Port : 8506
Alert TCP Port : 8507
Logging TCP Port : 8508
Applicable to:
NS-series Sensors