show intfport

Prev Next

This command shows the status of the specified Sensor port. Note that specifying a non-existent port results in an error.

Syntax:

show intfport <port>

Parameter

Description

<port>

Sets the port for which the status is to be displayed.

Valid port numbers for NS-series Sensors (except NS3600) are: g0/1 | g0/2 | g1/1 | g1/2 | g1/3 | g1/4 | g1/5 | g1/6 | g1/7 | g1/8 | g1/9 | g1/10 | g1/11 | g1/12 | g2/1 | g2/2 | g2/3 | g2/4 | g2/5 | g2/6 | g2/7 | g2/8 | g2/9 | g2/10 | g2/11 | g2/12 | g3/1 | g3/2 | g3/3 | g3/4 | g3/5 | g3/6 | g3/7 | g3/8 | WORD | all

Valid port-pairs for NS3600 Sensor are: 1-2 | 3-4 | 5-6 | 7-8 | 9-10 | 11-12 | 13-14

Information displayed by the show intfport command includes the following:

  • Whether the port's administrative status is enabled or disabled

  • The Sensor's operational status

  • The Sensor's operating mode

  • Whether full-duplex mode is enabled

  • The port's configured traffic direction (inside or outside)

  • The speed of the 10/100 ports, if applicable

  • The speed of the Gigabit ports, if applicable

  • The peer port's supported link mode

  • The peer ports negotiated duplex and speed

  • The auto-negotiating configuration

  • Total packets received

  • Total packets sent

  • Total CRC errors received

  • Total CRC errors sent

  • Whether the flow control is on (this applies only to Sensor gigabit ports)

Sample Output:

For Sensors, the output is as shown below:

intruShell@john> show intfport g1/2

Displaying port g1/2

Administrative Status : ENABLED (since Thu Jan 5 03:36:51 2023)

Operational Status : UP (since Thu Jan 5 03:38:02 2023)

Operating Mode : INLINE_FAIL_OPEN_ACTIVE

Duplex : FULL

Port Connected to : OUTSIDE

Port Speed : 10 GBPS

Actual Port Property : Fiber, Trellix Certified

Configured Port Property: Fiber, Allow any vendor certified connector

Additional Porttype Info:

Total Packets Received : 882391

Total Packets Sent : 882191

Total CRC Errors Rcvd : 0

Total Other Errors Rcvd : 0

Total CRC Errors Sent : 0

Total Other Errors Sent : 0

Flow Control Status : OFF

Fail-Open Switch : PRESENT

Fail-Open Port : INLINE

Layer 2 Status : DISABLED

Applicable to:

NS-series and Virtual IPS Sensors. The command does not apply to Virtual Security System instances; use the show ingress-egress stat command instead.