This command shows the status of the specified Sensor port. Note that specifying a non-existent port results in an error.
Syntax:
show intfport <port>
Parameter | Description |
|---|---|
<port> | Sets the port for which the status is to be displayed. Valid port numbers for NS-series Sensors (except NS3600) are: g0/1 | g0/2 | g1/1 | g1/2 | g1/3 | g1/4 | g1/5 | g1/6 | g1/7 | g1/8 | g1/9 | g1/10 | g1/11 | g1/12 | g2/1 | g2/2 | g2/3 | g2/4 | g2/5 | g2/6 | g2/7 | g2/8 | g2/9 | g2/10 | g2/11 | g2/12 | g3/1 | g3/2 | g3/3 | g3/4 | g3/5 | g3/6 | g3/7 | g3/8 | WORD | all Valid port-pairs for NS3600 Sensor are: 1-2 | 3-4 | 5-6 | 7-8 | 9-10 | 11-12 | 13-14 |
Information displayed by the show intfport command includes the following:
Whether the port's administrative status is enabled or disabled
The Sensor's operational status
The Sensor's operating mode
Whether full-duplex mode is enabled
The port's configured traffic direction (inside or outside)
The speed of the 10/100 ports, if applicable
The speed of the Gigabit ports, if applicable
The peer port's supported link mode
The peer ports negotiated duplex and speed
The auto-negotiating configuration
Total packets received
Total packets sent
Total CRC errors received
Total CRC errors sent
Whether the flow control is on (this applies only to Sensor gigabit ports)
Sample Output:
For Sensors, the output is as shown below:
intruShell@john> show intfport g1/2
Displaying port g1/2
Administrative Status : ENABLED (since Thu Jan 5 03:36:51 2023)
Operational Status : UP (since Thu Jan 5 03:38:02 2023)
Operating Mode : INLINE_FAIL_OPEN_ACTIVE
Duplex : FULL
Port Connected to : OUTSIDE
Port Speed : 10 GBPS
Actual Port Property : Fiber, Trellix Certified
Configured Port Property: Fiber, Allow any vendor certified connector
Additional Porttype Info:
Total Packets Received : 882391
Total Packets Sent : 882191
Total CRC Errors Rcvd : 0
Total Other Errors Rcvd : 0
Total CRC Errors Sent : 0
Total Other Errors Sent : 0
Flow Control Status : OFF
Fail-Open Switch : PRESENT
Fail-Open Port : INLINE
Layer 2 Status : DISABLED
Applicable to:
NS-series and Virtual IPS Sensors. The command does not apply to Virtual Security System instances; use the show ingress-egress stat command instead.