--- title: "show powersupply" slug: "show-powersupply-3" tags: ["Product Usage", "IPS 11.1.x"] updated: 2026-11-19T12:30:07Z published: 2026-11-19T12:30:07Z canonical: "docs.trellix.com/show-powersupply-3" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # show powersupply When executed, this CLI command displays the Sensor power supply information. **Syntax:** `show powersupply` **Sample output for NS3600 Sensor with chassis version 0.1:** ``` intruShell@NS3600> show powersupply ==== PSU Status ==== PSU Model: FSP300-50RFB PSU Firmware: 001 Vin: 230.00 V Vout: 12.14 V Iout: 5.64 A Pin: 92.00 W Pout: 83.00 W Ambient Temp: 30.00 C PSU1 Temp: 33.00 C PSU2 Temp: 25.00 C Fan Speed: 3148 rpm Status: OK Vout Status: OK Iout Status: OK Temp Status: OK Power Supply PRESENT health = OK ``` **Sample output for NS3600 Sensor with chassis version 0.0:** ``` intruShell@NS3600> show powersupply Power Supply                 PRESENT    health = OK ``` **Sample output for other NS-series Sensors:** `intruShell@john> show powersupply` `Power Supply (A) : Present : health = OK` `Power Supply (B) : Present : health = NOPOWER` **Applicable to:** NS-series Sensors