--- title: "show savedalertinfo" slug: "show-savedalertinfo-3" tags: ["Product Usage", "IPS 11.1.x"] updated: 2026-11-19T12:30:07Z published: 2026-11-19T12:30:07Z canonical: "docs.trellix.com/show-savedalertinfo-3" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # show savedalertinfo In the event that connectivity between the Sensor and the Manager is interrupted, the Sensor saves alert data internally. This data is sent to the Manager when connectivity is re-established and the internal information is deleted. This command shows the number of alerts and packet logs that have been saved within the Sensor. Information displayed by the `show savedalertinfo` command includes the following: - Whether a file of saved alerts exists (if the connectivity between Sensor and Manager is currently established, no file will exist) - Number of saved alerts and their size - Whether a file of saved packet logs exists - Number of saved packet logs and their size This command has no parameters. **Syntax:** `show savedalertinfo` **Sample Output:** `intruShell@john> show savedalertinfo` `Saved Alert Status : Alerts = 456, Size = 81168` `Saved Packet Status : No Saved File` **Applicable to:** NS-series Sensors