show sbcfg

Prev Next

The show sbcfg command displays various datapath configuration. This command has no parameters.

Syntax:

show sbcfg

Sample Output:

IntruDbg#> show sbcfg

IP CFG

IPFragmentTimer 30

OverlapOption OLD_DATA

TTLConfigMode NO_TTL_CHECKING

TTLThreshold 32

TTLResetValue 32

SmallestFragmentSize 256

SmallestFragmentThreshold 10000

IP Fragment Reassembly ENABLE

IPV6OverlapOption OLD_DATA

IPV6SmallestFragmentSize 48

IPV6SmallestFragmentThreshold 10000

TCP CFG

SupportedUDPFlows 800000

TCBInactivityTimer 10

TCPSegmentTimer 60

TCP2MSLTimer 10

InactiveFlowRstEnabled 2

DropReTxTCPEnabled 2

ColdStartTime 60

ColdStartDropAction FORWARD_FLOWS

NormalizationOnOffOption OFF

TcpOverlapOption NEW_DATA

SynAckPermittedOption 1

TCPOptionThreshold 100

DropOnPAWSFail ENABLE

TimeStampEchoMatchFail ENABLE

DropMD5Option ENABLE

UnsolicitedUDPPktsTimeout 60

SynProxyEnable DISABLE

AckScanDiscardTime 15

HalfOpenConnResetEnable RST_3WH_DISABLE

OutOfContextTcpPktEnable PERMIT_OUT_OF_ORDER

synCookieConfig Inbound-DISABLE Outbound-DISABLE

synCookieInboundThreshold 102400

synCookieOutboundThreshold 102400

synCookieMss 536

Tcpudpicmpchecksumerror Drop

flow volume threshold is 0MB.

DNSRedirectConfig disabled

Syn Cookie TCP Reset Send Enable status : Enabled (1)

DNS sinkhole TTL 720

DNS sinkhole IP 127.0.0.1

Oversubscription value: 0

BackendLimit Value: 0x1c2002d

INTF PORT 67

OperatingMode INLINE_FAIL_OPEN

FullDuplex ENABLED

InOutType OUTSIDE

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 0

ALERT THROTTLE CFG

CorrelationTime 5

PKTLOG CFG

MaxPktsPerFlow 1000

DOS CFG

DosPktLogging DISABLED

FAILOVER CFG

FailoverAction DISABLED

FailoverMode FAILOVER_MODE_STANDALONE

SSL CFG

SessionCacheLifetime 5

SupportAction 0

PktLogging DISABLED

ResponseProcEnable DISABLED

ACL Log Alert CFG

Alert Logging Disabled

DNSPROTECTION IPV4 CFG

No IPv4 DNS Protection IP's are configured

DNSPROTECTION IPV6 CFG

No IPv6 DNS Protection IP's are configured

SENSOR LOAD CFG

Sensor Load Computation is set to off

TUNNELING CFG

Tunneling is disabled

OVERSUBSCRIPTION CFG

Oversubscription level 0

IPS SIMULATION CFG

Ips Simulation is disabled

PKTDROP SYSEVENT CFG

PktDrop sysevent is disabled

IP REASSEMBLY TIMEOUT FORWARD CFG

IP Reassembly timeout forward is disabled

IP Reassembly timeout in milli second is 0

BDD threshold value : 20

BDD threshold value : 20

LDPENDING CFG

LDPENDING CFG is set to actual-load

Miscellaneous CFG

Misc Flags 256

Mon Port Ping Status : Disabled

IBAC Host Auth Status : Enabled

Sibyte Smpt Load Balancing Status : Disabled

IPS for Unknown UDP is enabled

EZ-LOG-ALERT CFG

EzAlertLogging 5

NBAD CFG

NBAD Sensor IP Address 12.1.1.11

NBAD Sensor Port 9996

NBAD IPS Primary Mon Port Id 34

NBAD IPS Secondary Mon Port Id 2

NBAD OS Finger Printing Status 0

NBAD App Finger Printing Status 0

NBAD SSL Flow Data Capture Status 0

NBAD TCP Capture Config : Enabled

NBAD UDP Capture Config : Enabled

NBAD ICMP Capture Config : Enabled

Miscellaneous CFG

TAPA Protocol Config : 0

Latency Monitor Status : 0

Artemis Detection Mode : 1

Malware UD Detection Mode : 1

GTIfilelookup timeout : 6

Overwrite GZIP : 0

Unknown Proto Scan Depth : 256

NAC DHCP Pxe Config : 39321602

L7 DCap Percent Flows : Configured-5, Used-20

L7 DCap Buffer Size : 1500

Misc Flags 256

Mon Port Ping Status : Disabled

IBAC Host Auth Status : Enabled

Unknown Proto Scandepth Status : Enabled

Sibyte Smpt Load Balancing Status : Disabled

AppId Stats Alert Status : Enabled

MPE Additional CFG

Number of Additional MPE IP Addresses 0

NAC host tracking configuration

NAC host tracking disabled

Dxl Config

EPO IP4 0.0.0.0

EPO IP6 ::

EPO IP TYPE 4

EPO PORT 8443

EPO Action 2

DXL Enable/Disable 2

MATD CFG

IP Address type = 4

Server IPv4 = 10.213.17x.xxx

MATD Profile/User Name = nsp

MATD Profile/User Id = 2

Applicable to:

NS-series Sensors