show sbcfg

Prev Next

The show sbcfg command displays various datapath configuration. This command has no parameters.

Syntax:

show sbcfg

Sample Output:

IntruDebug#> show sbcfg

IP CFG

IPFragmentTimer 30

OverlapOption OLD_DATA

TTLConfigMode NO_TTL_CHECKING

TTLThreshold 32

TTLResetValue 32

SmallestFragmentSize 256

SmallestFragmentThreshold 10000

IP Fragment Reassembly ENABLE

IPV6OverlapOption OLD_DATA

IPV6SmallestFragmentSize 48

IPV6SmallestFragmentThreshold 10000

TCP CFG

SupportedUDPFlows 100000

TCBInactivityTimer 10

TCPSegmentTimer 60

TCP2MSLTimer 10

InactiveFlowRstEnabled 2

DropReTxTCPEnabled 2

ColdStartTime 60

ColdStartDropAction FORWARD_FLOWS

NormalizationOnOffOption OFF

TcpOverlapOption NEW_DATA

SynAckPermittedOption 1

TCPOptionThreshold 100

DropOnPAWSFail ENABLE

TimeStampEchoMatchFail ENABLE

DropMD5Option ENABLE

UnsolicitedUDPPktsTimeout 60

SynProxyEnable DISABLE

AckScanDiscardTime 15

HalfOpenConnResetEnable RST_3WH_DISABLE

OutOfContextTcpPktEnable PERMIT_OUT_OF_ORDER

synCookieConfig Inbound-DISABLE Outbound-DISABLE

synCookieInboundThreshold 102400

synCookieOutboundThreshold 102400

synCookieMss 536

Tcpudpicmpchecksumerror Drop

flow volume threshold is 0MB.

DNSRedirectConfig disabled

Syn Cookie TCP Reset Send Enable status : Enabled (1)

DNS sinkhole TTL 720

DNS sinkhole IP 127.0.0.1

Oversubscription value: 0

BackendLimit Value: 0x1c2002d

INTF PORT 0

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType INSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 0

INTF PORT 1

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType OUTSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 0

INTF PORT 2

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType INSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 3

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType OUTSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 4

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType INSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 5

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType OUTSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 6

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType INSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 7

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType OUTSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 8

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType INSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 9

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType OUTSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 10

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType INSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 11

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType OUTSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 12

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType INSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 13

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType OUTSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 14

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType INSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 15

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType OUTSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 16

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType INSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 17

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType OUTSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 18

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType INSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 19

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType OUTSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 20

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType INSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 21

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType OUTSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 22

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType INSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 23

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType OUTSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 24

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType INSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 25

OperatingMode INLINE_FAIL_CLOSED

FullDuplex ENABLED

InOutType OUTSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 1

INTF PORT 26

OperatingMode INLINE_FAIL_OPEN

FullDuplex ENABLED

InOutType INSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 0

INTF PORT 27

OperatingMode INLINE_FAIL_OPEN

FullDuplex ENABLED

InOutType OUTSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 0

INTF PORT 28

OperatingMode INLINE_FAIL_OPEN

FullDuplex ENABLED

InOutType INSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 0

INTF PORT 29

OperatingMode INLINE_FAIL_OPEN

FullDuplex ENABLED

InOutType OUTSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 0

INTF PORT 30

OperatingMode INLINE_FAIL_OPEN

FullDuplex ENABLED

InOutType INSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 0

INTF PORT 31

OperatingMode INLINE_FAIL_OPEN

FullDuplex ENABLED

InOutType OUTSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 0

INTF PORT 32

OperatingMode INLINE_FAIL_OPEN

FullDuplex ENABLED

InOutType INSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 0

INTF PORT 33

OperatingMode INLINE_FAIL_OPEN

FullDuplex ENABLED

InOutType OUTSIDE

FEC Invalid

Monitoring Port IP - 0.0.0.0

Monitoring Port Netmask - 0.0.0.0

Monitoring Port Gateway - 0.0.0.0

Monitoring Port Vlan ID - 0

Monitoring Port NBAD Config Status - 0

Monitoring Port AppId Stats Alert Config Status - 0

RESP PORT 1

AdminStatus ENABLED

Operational Status : Down

FullDuplex ENABLED

Speed 3

PktDestination SWITCH

ALERT THROTTLE CFG

CorrelationTime 5

PKTLOG CFG

MaxPktsPerFlow 1000

DOS CFG

DosPktLogging DISABLED

FAILOVER CFG

FailoverAction DISABLED

FailoverMode FAILOVER_MODE_STANDALONE

SSL CFG

SessionCacheLifetime 5

SupportAction 0

PktLogging DISABLED

ShKey Decrypt DISABLED

ResponseProcEnable DISABLED

Configured SSL inbound mode 0

Current SSL inbound mode 0

Configured SSL outbound mode 0

Current SSL outbound mode 0

Outbound PktLogging DISABLED

Outbound SessionCacheLifetime : 5

Outbound Unknown Server Certificate : 1

Outbound Untrusted Server Certificate : 3

Outbound Unsupported cipher suite : 1

Outbound Unsupported Server Certificate : 1

Outbound Unknown URL Category : 0

ACL Log Alert CFG

Alert Logging Disabled

DNSPROTECTION IPV4 CFG

No IPv4 DNS Protection IP's are configured

DNSPROTECTION IPV6 CFG

No IPv6 DNS Protection IP's are configured

SENSOR LOAD CFG

Sensor Load Computation is set to off

TUNNELING CFG

Tunneling is disabled

OVERSUBSCRIPTION CFG

Oversubscription level 0

IPS SIMULATION CFG

Ips Simulation is disabled

PKTDROP SYSEVENT CFG

PktDrop sysevent is disabled

IP REASSEMBLY TIMEOUT FORWARD CFG

IP Reassembly timeout forward is disabled

IP Reassembly timeout in milli second is 0

BDD threshold value : 20

BDD threshold value : 20

BDD threshold value for base64-smtp: 0

Max Unknown Port SSL Connections: 0

LDPENDING CFG

LDPENDING CFG is set to actual-load

Miscellaneous CFG

Misc Flags 41216

Mon Port Ping Status : Disabled

Datapath attack detection monitoring : Disabled

IBAC Host Auth Status : Enabled

Sibyte Smpt Load Balancing Status : Disabled

IPS for Unknown UDP is enabled

EZ-LOG-ALERT CFG

EzAlertLogging 5

NBAD CFG

NBAD Sensor IP Address 0.0.0.0

NBAD Sensor Port 0

NBAD IPS Primary Mon Port Id 1

NBAD IPS Secondary Mon Port Id 2

NBAD OS Finger Printing Status 0

NBAD App Finger Printing Status 0

NBAD SSL Flow Data Capture Status 0

NBAD TCP Capture Config : Enabled

NBAD UDP Capture Config : Enabled

NBAD ICMP Capture Config : Disabled

Miscellaneous CFG

TAPA Protocol Config : 0

Latency Monitor Status : 0

Artemis Detection Mode : 1

Malware UD Detection Mode : 1

GTIfilelookup timeout : 6

Overwrite GZIP : 0

Unknown Proto Scan Depth : 256

NAC DHCP Pxe Config : 39321602

L7 DCap Percent Flows : 20

L7 DCap Buffer Size : 1500

Misc Flags 41216

Mon Port Ping Status : Disabled

Datapath attack detection monitoring : Disabled

IBAC Host Auth Status : Enabled

Unknown Proto Scandepth Status : Enabled

Sibyte Smpt Load Balancing Status : Disabled

AppId Stats Alert Status : Enabled

Requested Snort Rule Engine Config : Trellix Snort

Active Snort Rule Engine Config : Trellix Snort

MPE Additional CFG

Number of Additional MPE IP Addresses 0

NAC host tracking configuration

NAC host tracking disabled

Dxl Config

EPO IP4 10.213.169.103

EPO IP6 ::

EPO IP TYPE 4

EPO PORT 8443

EPO Action 3

EPO Username admin

DXL Enable/Disable 1

TIS CFG

IP Address type = 0

TIS Profile/User Name = nsp

TIS Profile/User Id = 2

Applicable to:

NS-series Sensors