The new docs.trellix.com features a modernized UI and AI-powered conversational search. Content is currently available in English, with additional languages launching in early November 2026. We hope you enjoy the updated experience.

show userconfigvolumedosthreshold

Prev Next

This command displays the specified user-defined DoS threshold for alerting on volume for a particular packet type.

Syntax:

show userconfigvolumedosthreshold <dos-measure-name> <direction>

Parameter

Description

<dos-measure-name>

Indicates the DoS measure name: one of 'tcp-syn', 'tcp-syn-ack', 'tcp-fin', 'tcp-rst', 'udp', 'icmp-echo', 'icmp-echo-reply', 'icmp-non-echo-reply', 'ip-fragment', 'non-tcp-udp-icmp'

<direction>

Indicates the direction. It can be 'inbound' or 'outbound'.

Sample Output:

intruShell@Sensor-6050> show userconfigvolumedosthreshold icmp-echo-reply inbound

User did not configure threshold for icmp-echo-reply inbound

Example:

show userconfigvolumedosthreshold icmp-echo-reply inbound returns one of the following responses:

  • The threshold value configured using set userconfigvolumedosthreshold icmp-echo-reply inbound

  • If the threshold was not configured, the message User did not configure threshold for icmp-echo-reply inbound

Applicable to:

NS-series Sensors