--- title: "status" slug: "status-10" tags: ["Product Usage", "IPS 11.1.x"] updated: 2026-11-19T12:30:20Z published: 2026-11-19T12:30:20Z canonical: "docs.trellix.com/status-10" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # status This command displays Sensor system status, such as System Health, Manager communication, signature set details, total number of alerts detected, and total number of alerts sent to the Manager. This command has no parameters. **Syntax:** `status` **Sample Output:** For Sensor, the output is as shown below: `intruShell@john> status` `[Sensor]` `System Initialized : yes` `System Health Status : good` `System Capacity : 750 Mbps` > [!NOTE] > Note > > System Capacity is displayed only for NS9600, NS9500, NS7600, NS7500, NS3600, and NS3500 Sensors. `Layer 2 Status : normal (IDS/IPS)` `Installation Status : complete` `IPv6 Status : Parse and Detect Attacks` `Reboot Status : Not Required` `Guest Portal Status : up` `Hitless Reboot : Not-Available` `Last Reboot reason : reboot issued from CLI` `Mode Change Status : Not-Applicable` `[Signature Status]` `Present : yes` `Version : 11.9.0.5` `Power up signature : good` `Geo Location database : Present` `DAT file : Present` `Version : 3376.0` `[Manager Communications]` `Trust Established : yes (Self Signed cert support)` `Alert Channel : up` `Log Channel : up` `Authentication Channel : up` `Last Error : None` `Alerts Sent : 961` `Logs Sent : 974` `[Alerts Detected]` `Signature : 4246 Alerts Suppressed : 3483` `Scan : 0 Denial of Service : 2` `Malware : 4` `[NTBA Communication]` `Status : up` `IP : 10.213.174.132` `Port : 8505` `[TIS Communication]` `Status : up` `IP : 10.200.100.60` `Port(Secure) : 8505` The same status message appears in an NTBA Appliance also. > [!NOTE] > Note > > In NS9300 Sensor, if the Sensor reboots due to mismatch in software version, the `status` command specifies the reason `recovered from sw version mismatch` in `Last Reboot reason`. > [!NOTE] > Note > > For NS9600, NS9500, and NS3500 Sensors, the `status` command also displays the current throughput based on the license purchased. If signature set is not detected in the Sensor, `No license` is displayed. > [!NOTE] > Note > > If there is a failure in establishing trust between the Sensor and Manager due to mismatch in shared secret key, the `Last Error` displays the message `Alert Channel - Install Keys Mismatch`. In such an instance, check the shared secret key on the Manager and set it on the Sensor using `set sensor sharedsecretkey` command. **Applicable to:** NS-series Sensors