--- title: "status" slug: "status-3" tags: ["Product Usage", "IPS 10.1.10"] updated: 2026-10-05T15:41:06Z published: 2026-10-05T15:41:06Z canonical: "docs.trellix.com/status-3" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # status This command displays Sensor system status, such as System Health, Manager communication, signature set details, total number of alerts detected, and total number of alerts sent to the Manager. This command has no parameters. **Syntax:** status **Sample Output:** For Sensor, the output is as shown below: intruShell@john> status [Sensor] System Initialized : yes System Health Status : good System Capacity : 750 Mbps > [!NOTE] > Note > > System Capacity is displayed only for NS9500, NS7500, and NS3500 Sensors. Layer 2 Status : normal (IDS/IPS) Installation Status : complete IPv6 Status : Parse and Detect Attacks Reboot Status : Not Required Guest Portal Status : up Hitless Reboot : Not-Available Last Reboot reason : reboot issued from CLI [Signature Status] Present : yes Version : 8.6.0.6 Power up signature : good Geo Location database : Present DAT file : Present Version : 318.0 [Manager Communications] Trust Established : yes (RSA 1024-bit or 2048-bit) Alert Channel : up Log Channel : up Authentication Channel : up Last Error : None Alerts Sent : 961 Logs Sent : 974 [Alerts Detected] Signature : 4246 Alerts Suppressed : 3483 Scan : 0 Denial of Service : 2 Malware : 0 [NTBA Communication] Status : up IP : 10.213.174.132 Port : 8505 [MATD Communication] Status : up IP : 10.213.174.134 Port : 8506 The same status message appears in an NTBA Appliance also. > [!NOTE] > Note > > In NS9300 Sensor, if the Sensor reboots due to mismatch in software version, the status command specifies the reason recovered from sw version mismatch in Last Reboot reason. > [!NOTE] > Note > > For NS9500 and NS3500 Sensors, the status command also displays the current throughput based on the license purchased. If signature set is not detected in the Sensor, No license is displayed. > [!NOTE] > Note > > If there is a failure in establishing trust between the Sensor and Manager due to mismatch in shared secret key, the Last Error displays the message Alert Channel - Install Keys Mismatch. In such an instance, check the shared secret key on the Manager and set it on the Sensor using set sensor sharedsecretkey command. **Applicable to:** NS-series Sensors