--- title: "System environmental limits" slug: "system-environmental-limits" updated: 2026-09-08T19:56:54Z published: 2026-09-08T19:56:54Z canonical: "docs.trellix.com/system-environmental-limits" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # System environmental limits ### | Parameter | State or category | ATD-3200 and ATD 6200 | ATD-3100 and ATD 6100 | ATD-3000 | ATD-6000 | | --- | --- | --- | --- | --- | --- | | **Temperature** | **Operating** | - **ASHRAE Class A2** — Continuous Operation, 10º C to 35º C (50º F to 95º F) with the maximum rate of change not to exceed 10 C per hour - **ASHRAE Class A3** — Includes operation up to 40º C for up to 900 hours per year - **ASHRAE Class A4** — Includes operation up to 45º C for up to 90 hours per year | - **ASHRAE Class A2** — Continuous Operation, 10º C to 35º C (50º F to 95º F) with the maximum rate of change not to exceed 10 C per hour - **ASHRAE Class A3** — Includes operation up to 40º C for up to 900 hours per year - **ASHRAE Class A4** — Includes operation up to 45º C for up to 90 hours per year | +10°C to +35° C (+50°F to + 95°F) with the maximum rate of change not to exceed 10°C per hour | +10º C to +35º C (+50ºF to +95ºF) with the maximum rate of change not to exceed 10°C per hour | | **Shipping** | -40º C to 70º C (-40º F to 158º F) | -40º C to 70º C (-40º F to 158º F) | -40°C to +70°C (-40°F to +158°F) | -40°C to +70°C (-40°F to +158°F) | | **Altitude** | **Operating** | Support operation up to 3050 meters (10,000 feet) with ASHRAE class deratings | Support operation up to 3050 meters (10,000 feet) with ASHRAE class deratings | Support operation up to 3050 meters (10,000 feet) | Support operation up to 3050 meters (10,000 feet) | | **Humidity** | **Shipping** | 50% to 90%, non-condensing with a maximum wet bulb of 28°C (at temperatures from 25°C to 35°C) | 50% to 90%, non-condensing with a maximum wet bulb of 28°C (at temperatures from 25°C to 35°C) | - **Operational** — 10% to 90% - **Non-operational** — 90% at 35°C | - **Operational** — 10% to 90% - **Non-operational** — 50% to 90% with a maximum wet bulb of 28°C (at temperatures from 25°C to 35°C) | | **Shock** | **Operating** | Half sine, 2 g peak, 11 milliseconds | Half sine, 2 g peak, 11 milliseconds | Half sine, 2 g peak, 11 milliseconds | Half sine, 2 g peak, 11 milliseconds | | **Unpackaged** | Trapezoidal, 25 g, velocity change is based on packaged weight | Trapezoidal, 25 g, velocity change is based on packaged weight | Trapezoidal, 25 g, velocity change 136 inches/second (≧40 lbs to < 80 lbs) | Trapezoidal, 25 g, velocity change is based on packaged weight | | **Packaged** | International Safe Transit Association (ISTA) Test Procedure 3A 2008 | International Safe Transit Association (ISTA) Test Procedure 3A 2008 | Non-palletized free fall in height 24 inches (≧40 lbs to < 80 lbs) | - Product Weight: ≥ 40 to < 80 - Non-palletized Free Fall Height = 18 inches - Palletized (single product) Free Fall Height = NA | | **Vibration** | **Unpackaged** | 5 Hz to 500 Hz, 2.20 g RMS random | 5 Hz to 500 Hz, 2.20 g RMS random | 5 Hz to 500 Hz, 2.20 g RMS random | 5 Hz to 500 Hz, 2.20 g RMS random | | **Packaged** | International Safe Transit Association (ISTA) Test Procedure 3A 2008 | International Safe Transit Association (ISTA) Test Procedure 3A 2008 | | 5 Hz to 500 Hz, 1.09 g RMS random | | **AC-DC** | **Voltage** | ATD-3200 - 115V - 5.4 Amps - 220V - 2.7 Amps ATD-6200 - 115V -6.7 Amps - 220V -3.4 Amps | ATD-3100 - 115V - 5.4 Amps - 220V - 2.7 Amps ATD-6100 - 115V -6.7 Amps - 220V -3.4 Amps | 100 - 240 V at 5.8 Amps | 100 - 240 V. 8.5 Amps | | **Frequency** | 47 Hz to 63 Hz | 47 Hz to 63 Hz | 50 - 60 Hz | 50 - 60 Hz | | **Source Interrupt** | No Loss of data for power line drop-out of 12 milliseconds | No Loss of data for power line drop-out of 12 milliseconds | | | | **Surge (Operating and non-operating)** | Unidirectional | Unidirectional | | | | **Line to earth Only** | - AC Leads — 2.0 kV - I/O Leads — 1.0 kV - DC Leads — 0.5 kV | - AC Leads — 2.0 kV - I/O Leads — 1.0 kV - DC Leads — 0.5 kV | | | | **ESD** | **Air Discharged** | 12.0 kV | 12.0 kV | +/-12 KV except I/O port +/- 8 KV per Environmental test specification | 12.0 kV | | **Contact Discharge** | 8.0 kV | 8.0 kV | | 8.0 kV | | **Acoustic noise** | **Power level <300 W** | 7.0 BA | 7.0 BA | Sound power: 7.0 BA in operating conditions at typical office ambient temperature (23 +/- 2 degrees C) | Sound power: 7.0 BA in operating conditions at typical office ambient temperature (23 +/- 2 degrees °C) | | **Power level >300 W** | | **Power level >600 W** | | **Power level >1000 W** | | **Certifications** | **Safety certification** | | | UL 1950, CSA-C22.2 No. 950, EN-60950, IEC 950, EN 60825, 21CFR1040 CB license and report covering all national country deviations | UL 1950, CSA-C22.2 No. 950, EN-60950, IEC 950, EN 60825, 21CFR1040 CB license and report covering all national country deviations | | **EMI certification** | | | FCC Part 15, Class A (CFR 47) (USA) ICES-003 Class A (Canada), EN55022 Class A (Europe), CISPR22 Class A (Int'l) | FCC Part 15, Class A (CFR 47) (USA) ICES-003 Class A (Canada), EN55022 Class A (Europe), CISPR22 Class A (Int'l) | :