--- title: "The Front View" slug: "the-front-view-1" tags: ["Network Security (NX)", "Hardware"] updated: 2026-09-12T20:36:24Z published: 2026-09-12T20:36:24Z canonical: "docs.trellix.com/the-front-view-1" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # The Front View ![NX_4600_FrontView.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-84816106-fefa-9592-5070-0c83a91c2706.png?sv=2026-02-06&spr=https&st=2026-11-20T14%3A20%3A33Z&se=2026-11-20T15%3A20%3A33Z&sr=c&sp=r&sig=0Wax7l3mBWP4NFC2neDomlqqYSrXdjVb0UZv4vIaYQM%3D) | 1. Power button | The main power switch applies or removes primary power from the power supply to the server but maintains standby power. Unplug the appliance before servicing. | | | --- | --- | --- | | 2. Reset Button | Reboots the system. | | | 3. Power LED | Steady on | Power on | | Blinking at 4 Hz | Checking BIOS/BMC integrity | | Blinking at 4Hz and "i" LED is blue | BIOS firmware updating | | Two blinks at 4 Hz, one pause 2 Hz and "i" LED blue | BMC firmware updating | | Blinking at 1 Hz and "i" LED red | Fault detected | | 4. LAN 1 LED | Indicates network activity on a GLAN1 when flashing. | | | 5. Power Failure LED | Indicates a power supply module has failed. | | | 6. HDD Activity LED | Indicates activity on the hard drive when flashing. | | | 7. LAN 2 LED | Indicates network activity on a LAN when flashing. | | | 8. Information LED | Alerts operator to several states: | | Red, solid | An overheat condition has occurred | | Red, blinking at 1 Hz | Fan failure, check for an inoperative fan | | Red, blinking at 0.25 Hz | Power failure, check for a non-operational power supply | | Red, solid, with Power LED blinking green | Fault detected | | Blue and red, blinking at 10 Hz | Recovery mode | | Blue, solid | UID has been activated locally to locate the server in a rack environment | | Blue, blinking at 1 Hz | UID has been activated using the BMC to locate the server in a rack environment | | Blue, blinking at 2 Hz | BMC is resetting | | Blue, blinking at 4 Hz | BMC is setting factory defaults | | Blue, blinking at 10 Hz with Power LED blinking green | BMC/BIOS firmware is updating | | 9. Drive Device LED | Each drive carrier displays two status LEDs on the front of the carrier. | | | 10. Drive Device LED | Each drive carrier displays two status LEDs on the front of the carrier. | | #### Drive Carrier LED Indicators The chassis includes externally accessible SAS/SATA drives. Each drive carrier displays two status LEDs on the front of the carrier. - Green: When illuminated, this LED indicates drive activity. It blinks on and off when that particular drive is being accessed This function is controlled by the backplane. - Red: When illuminated, this LED indicates a drive failure. You should be notified by your system management software. #### Chassis ![X12SPW_Chassis.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-c12f1538-6052-be16-34b9-8727fcd034f3(2).PNG?sv=2026-02-06&spr=https&st=2026-11-20T14%3A20%3A33Z&se=2026-11-20T15%3A20%3A33Z&sr=c&sp=r&sig=0Wax7l3mBWP4NFC2neDomlqqYSrXdjVb0UZv4vIaYQM%3D) 1. **Disk Drive Carrier:** Each carrier can house a hot-swappable disk drive. A drive slot map displays the disk slot numbers on top of the appliance. 2. **Handle Release:** Press this tab to release the handle. Use the handle to pull the disk drive carrier from the chassis. :