--- title: "Troubleshooting" slug: "troubleshooting-27" tags: ["Hardware", "IPS 11.1.x"] updated: 2026-08-19T18:44:29Z published: 2026-09-17T07:33:47Z canonical: "docs.trellix.com/troubleshooting-27" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Troubleshooting During normal in-line fail-open operation of the Sensor, the fail-open switch constantly sends a heartbeat signal to the Sensor. If this signal does not return to the fail-open switch within a programmed interval, the fail-open switch removes the Sensor from the data path and moves into *bypass mode*, providing continuous data flow with little network interruption. While the fail-open switch is in bypass mode, traffic passes directly through it, bypassing the Sensor. When normal Sensor operation resumes, you might or might not need to manually re-enable the monitoring ports from the IPS Manager interface, depending on the activity leading up to the Sensor's failure. The following section describes how to return the Sensor to in-line mode.