--- title: "Troubleshooting" slug: "troubleshooting-28" tags: ["Hardware", "IPS 11.1.x"] updated: 2026-08-19T18:44:14Z published: 2026-09-17T07:33:47Z canonical: "docs.trellix.com/troubleshooting-28" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Troubleshooting During normal inline fail-open operation of the Sensor, the Control port on the Sensor supplies power and a heartbeat packet to the Fail-Open switch. If this signal is not sent to the Fail-Open switch within the 3-millisecond interval, the Fail-Open switch removes the Sensor from the data path and moves into **Bypass Mode**, providing continuous data flow with little network interruption. While the Fail-Open switch is in bypass mode, traffic passes directly through it, bypassing the Sensor. When normal Sensor operation resumes, you may or may not need to manually re-enable the monitoring ports from the Manager interface, depending on the activity leading up to the Sensor's failure. The following section describes how to return the Sensor to inline mode: