--- title: "Troubleshooting the Sensor" slug: "troubleshooting-the-sensor-1" tags: ["Hardware"] updated: 2026-09-24T13:07:15Z published: 2026-09-24T13:07:15Z canonical: "docs.trellix.com/troubleshooting-the-sensor-1" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Troubleshooting the Sensor This section lists some common installation problems, the possible causes, and the corresponding solutions. | Problem | Possible Cause | Solution | | --- | --- | --- | | LEDs are off. | The Sensor is turned off. | Restore Sensor power. | | Link LEDs are off. | The Sensor port cable is disconnected, or not seated properly. | Check the cables between the network devices and the Sensor monitoring ports | | Sensor is operational but the monitoring ports are not up. | Network device cables have been disconnected. | Check the cables and make sure they are properly connected to the network devices or Active Fail-Open kits. | | Sensor is operational and the cables are properly connected but it is not monitoring the traffic. | The Sensor ports have not been enabled in the Manager. | The Sensor will not monitor traffic on the ports unless the ports are enabled in the Manager. Ports are disabled in case of Sensor failure; you must re-enable them for Sensor monitoring to resume. | | Network or link problems | Improper cabling or port configuration | Make sure that the transmitting and receiving cables are properly connected to the network devices or Active Fail-Open kits. | | Runts or giants errors on switches and routers | Improper cabling or port configuration, or malfunctioning cables | Make sure that the transmitting and receiving cables are properly connected to the network devices or Active Fail-Open kits. Check that the port configurations are matching on both ends or replace the network cables. | | The system fault "Switch absent" appears on the **Faults** tab on the **Logs** page. | The Active Fail-Open Kit is disconnected. | Check the Active Fail-Open Kit and make sure it is properly connected to the Sensor. | You can monitor whether the health status of the Sensor(s) is in the ![GUID-C395F07B-D0CD-480A-BCC2-FB886010F5DD-low.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-5f3ecb5f-3b80-d67f-3d11-265ebca482f0(6).png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A29%3A25Z&se=2026-11-20T05%3A29%3A25Z&sr=c&sp=r&sig=sllm05DRW6HYnXg5VFxKOH5c7zVuw5pKW3KgH8QUDv4%3D) **Good** state from the **Devices** → **** → **Global** → **Sensor Health** → **Health Status** page. If you encounter any faults, Trellix recommends to take the required actions. For more information on how to check the health status of a Sensor and take actions as per requirement, refer to the section [Monitoring Sensor Health](/network-and-platform/docs/monitoring-sensor-health-4) in the *Trellix Intrusion Prevention System Product Guide*. For more information on the generated faults, refer to the section [Sensor Faults](/network-and-platform/docs/sensor-faults-4) in the *Trellix Intrusion Prevention System Product Guide*. > [!NOTE] > Note > > If any issues persist or you encounter problems in troubleshooting, contact Trellix Support for further assistance.