The new docs.trellix.com features a modernized UI and AI-powered conversational search. Content is currently available in English, with additional languages launching in early November 2026. We hope you enjoy the updated experience.

Types of fail-open

Prev Next

Internal fail-open

Some Sensor models provide fail-open through their in-built copper ports. Sensor models that provide in-built fail-open are:

  • NS-series: NS9600, NS9500, NS9300, NS9200, NS9100, NS7600, NS7500, NS7350, NS7250, NS7150, NS7300, NS7200, NS7100, NS5200, NS5100, NS3600, NS3500, NS3200, and NS3100

External fail-open

Fail-open switches are categorized in several ways. One categorization, as seen above, is based on functionality – active or passive. In addition, they are also categorized based on the type of ports and the corresponding type of cables that connect them to the Sensor and network device – copper or fiber. Copper and fiber fail-open switches are further categorized based on the maximum throughput that each model supports. Finally, every fail-open switch optionally has the facility to trigger alarms and send notifications to an SNMP manager.

Important

While choosing a fail-open switch, you must remember that certain fail-open switches are compatible only with certain Sensors. The comparison in the tables in upcoming sections provide details about which fail-open switches work with which Sensors. These tables contain a Model no. for each fail-open switch. The rest of the chapter frequently refers to the Model no. of each fail-open kit when explaining steps to perform various functions.

Important

All active fail-open switches support SNMP traps regardless of whether the switch is copper or fiber. The switch in such fail-open kits consists of a Management port. This allows you to assign an IP address to the fail-open switch and establish communication with an SNMP server through the network.

Fiber fail-open switches consist of two types: single mode and multi-mode fibers. The table below gives you some relevant details about both types of fiber optic fail-open switches. This is especially relevant because you must determine the type of fiber that is used your organization network before you decide which type of fail-open switch to use. Also, all product documentation for fail-open kits and decals on the fail-open switches will repeatedly refer to these parameters.

Single mode and multi-mode fiber optic fail-open switches

Type

Fiber thickness

Wavelength range

Single mode (Long reach)

8.5 µm

1300 nm to 1550 nm

Multi-mode (Short reach)

50 µm or 62.5 µm

850 nm to 1300 nm



Support for External Active Fail-Open Kits in Sensors with internal fail-open functionality

All Sensor port-pairs with internal or in-built fail-open functionality can also support active fail-open kits (refer to the section Active fail-open switches for compatibility information). For additional details, refer to the specific fail-open kit guides.

Using an external (active) fail-open switch has the following advantages over the in-built mode:

  • Lower latency in a bypass mechanism

  • Elimination of risk associated with a single point of failure