--- title: "Types of fail-open" slug: "types-of-fail-open" tags: ["Product Usage", "IPS 10.1.10"] updated: 2026-09-06T12:28:24Z published: 2026-10-05T15:41:20Z canonical: "docs.trellix.com/types-of-fail-open" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Types of fail-open ## Internal fail-open Some Sensor models provide fail-open through their in-built copper ports. Sensor models that provide in-built fail-open are: - **M-Series**: M-2950, M-2850, M1450, and M-1250, - **NS-series**: NS9500, NS9300, NS9200, NS9100, NS7500, NS7350, NS7250, NS7150, NS7300, NS7200, NS7100, NS5200, NS5100, NS3500, NS3200, and NS3100 ## External fail-open Fail-open switches are categorized in several ways. One categorization, as have seen above, is based on functionality – active or passive. In addition, they are also categorized based on the type of ports and the corresponding type of cables that connect them to the Sensor and network device – copper or fiber. Copper and fiber fail-open switches are further categorized based on the maximum throughput that each model supports. Finally, every fail-open switch optionally has the facility to trigger alarms and send notifications to an SNMP manager. > [!NOTE] > Important > > While choosing a fail-open switch, you must remember that certain fail-open switches are compatible only with certain Sensors. The comparison in the tables in upcoming sections provide details about which fail-open switches work with which Sensors. These tables contain a **Model no.** for each fail-open switch. The rest of the chapter frequently refers to the **Model no.** of each fail-open kit when explaining steps to perform various functions. > [!NOTE] > Important > > All active fail-open switches support SNMP traps regardless of whether the switch is copper or fiber. The switch in such fail-open kits consists of a Management port. This allows you to assign an IP address to the fail-open switch and establish communication with an SNMP server through the network. Fiber fail-open switches consist of two types: single mode and multi-mode fibers. The table below gives you some relevant details about both types of fiber optic fail-open switches. This is especially relevant because you must determine the type of fiber that is used your organization network before you decide which type of fail-open switch to use. Also, all product documentation for fail-open kits and decals on the fail-open switches will repeatedly refer to these parameters. | Type | Fiber thickness | Wavelength range | | --- | --- | --- | | Single mode (Long reach) | 8.5 µm | 1300 nm to 1550 nm | | Multi-mode (Short reach) | 50 µm or 62.5 µm | 850 nm to 1300 nm | **Support for External Active Fail-Open Kits in Sensors with internal fail-open functionality** All Sensor port-pairs with internal or in-built fail-open functionality (except *M-1250 and M-1450* ) can also support active fail-open kits (refer to the section [Active fail-open switches](/network-and-platform/docs/active-fail-open-switches) for compatibility information). For additional details, refer to the specific fail-open kit guides. Using an external (active) fail-open switch has the following advantages over the in-built mode: - Lower latency in a bypass mechanism - Elimination of risk associated with a single point of failure