--- title: "Update Gateway Anti-Malware Engine manually" slug: "update-gateway-anti-malware-engine-manually" tags: ["Install and Get Started", "IPS 10.1.10"] updated: 2026-09-23T09:38:00Z published: 2026-09-23T09:38:00Z canonical: "docs.trellix.com/update-gateway-anti-malware-engine-manually" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Update Gateway Anti-Malware Engine manually If you want to update the Gateway Anti-Malware Engine for an offline Sensor, you will need to manually download the appropriate software version and import it into the Manager. When the Gateway Anti-Malware engine is enabled for the first time, the engine is in uninitialized state when integrated with a Private GTI cloud. To receive a manual update, the Gateway Anti-Malware engine has to be in initialized state. To initialize the engine, the Sensor has to be online and connected to the Private GTI server to receive the update for the first time. Once the Gateway Anti-Malware engine is initialized after receiving the update from Private GTI server, you can push the updates to the Sensor. For subsequent manual Gateway Anti-Malware engine update, you can download the update and import it to the Manager. > [!NOTE] > Note > > It is important that you download a compatible version of Gateway Anti-Malware Engine files to make sure the update is successful. To ascertain which software versions are compatible with which versions of the Sensor software, refer to Gateway Anti-Malware Engine in the section How an Advanced Malware policy works in Trellix Intrusion Prevention System Product Guide. Perform the steps listed below to manually download the Gateway Anti-Malware Engine update files and deploy them to your Sensor. ## Task 1. Select **Devices** → **** → **Devices** → **** → **Setup** → **Name Resolution**. The DNS server is configured for the Sensor to reach the GTI server. 2. Using a recent version of your browser, go to the Gateway Anti-Malware Update Server URL: [https://contentsecurity.skyhigh.cloud/UPDATE](https://contentsecurity.skyhigh.cloud/UPDATE). 3. On the page that appears, review the terms and conditions and select the **I accept the terms and conditions** check-box, and click **Next Step**. Accept License Agreement ![](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/GUID-4A428871-0853-4A3B-BC34-01FEE356CF7B-low(1).jpg?sv=2026-02-06&spr=https&st=2026-11-20T06%3A53%3A55Z&se=2026-11-20T07%3A53%3A55Z&sr=c&sp=r&sig=XodtJCd2Dx9Pbpjq3t2c%2B5rr6eMMKhbD1gClU0VR94U%3D) You are routed to the next page where you will need to select the appropriate Trellix product. 4. On this page, click the drop-down to select **Trellix Intrusion Prevention System**, and click **Next Step**. Select update package ![](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/GUID-4557860D-6259-4851-AE75-483591F147E2-low(1).jpg?sv=2026-02-06&spr=https&st=2026-11-20T06%3A53%3A55Z&se=2026-11-20T07%3A53%3A55Z&sr=c&sp=r&sig=XodtJCd2Dx9Pbpjq3t2c%2B5rr6eMMKhbD1gClU0VR94U%3D) You are routed to the next page where you must enter the appropriate version of Sensor software you are using. 5. Under step 3: Specify version and build number ![](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/GUID-898AA48F-CAA9-4CBB-9AB6-A1793532A6C8-low(1).jpg?sv=2026-02-06&spr=https&st=2026-11-20T06%3A53%3A55Z&se=2026-11-20T07%3A53%3A55Z&sr=c&sp=r&sig=XodtJCd2Dx9Pbpjq3t2c%2B5rr6eMMKhbD1gClU0VR94U%3D) The success or failure of the update will vary depending on the Sensor and Manager software versions you are using. Review this table to know the various combinations and what version you must enter to make sure you download the appropriate Gateway Anti-Malware Engine version. | Manager | Sensor | Gateway Anti-Malware engine version downloaded | What you must enter... | | --- | --- | --- | --- | | 10.1.7.55 or later | 10.1.5.153 or later | 2021 | You must enter the Sensor software version as 10.1.5.x. | | 10.1.7.29 or later | 10.1.5.41 or later | 2019 version 0 | You must enter the Sensor software version as 10.1.5.x. | | 10.1.7.4 or later | 10.1.5.3 or later | 2017 version 2 | You must enter the Sensor software version as 10.1.5.x. | | 9.2.7.22 or later | 9.2.5.27 or later | 2017 version 2 | You must enter the Sensor software version as 9.2.5.x. | | 9.2.7.22 or later | 9.2.5.6 till 9.2.5.27 but does not include 9.2.5.27 | 2017 version 1 | You must enter the Sensor software version as 9.2.5.x. | | 9.2.7.9 (or any 9.2 Manager hotfix before 9.2.7.22) | 9.2.5.6 or later | NA | Manual import is not supported. | | 9.2.7.22 or later | 9.1.5.40 or later | 2017 version 1 | You must enter the Sensor software version as 9.1.5.x. | | 9.2.7.22 or later | 9.1.5.9 till 9.1.5.40 | 2014 | You must enter the Sensor software version as 9.1.5.x. | | Pre-9.2.7.9 | 9.2.5.6 or later | NA | Manual import is not supported. | 1. For **"Trellix Intrusion Prevention System" version**, enter 10.1 if your Sensor runs on 10.1.5.x version, or enter 9.2 if your Sensor runs on 9.2.5.x version. 2. For **"Trellix Intrusion Prevention System" build number**, enter 10.1.5.x if your Sensor runs on 10.1.5.x version, or enter 9.2.5.x if your Sensor runs on 9.2.5.x version. 3. Click **Next Step**. 6. Click **Generate Update Package**. Generate Update Package ![](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/GUID-0E22B27E-6F48-4523-97C0-DE4F82F56AFA-low(1).jpg?sv=2026-02-06&spr=https&st=2026-11-20T06%3A53%3A55Z&se=2026-11-20T07%3A53%3A55Z&sr=c&sp=r&sig=XodtJCd2Dx9Pbpjq3t2c%2B5rr6eMMKhbD1gClU0VR94U%3D) 7. Click **Download** and save the package to a convenient location. Download Update Package ![](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/GUID-A2A488D8-D118-4C4C-842A-555BEF1F3AA7-low(1).jpg?sv=2026-02-06&spr=https&st=2026-11-20T06%3A53%3A55Z&se=2026-11-20T07%3A53%3A55Z&sr=c&sp=r&sig=XodtJCd2Dx9Pbpjq3t2c%2B5rr6eMMKhbD1gClU0VR94U%3D) After the package is generated, you are shown details about the file such as filename, file size, MD5, SHA1, SHA256 checksums and date. 8. After the file is downloaded, log on to the Manager and go to **Manager** → **** → **Trellix IPS Protection Status**. Select **Manual Import** tab. The **Manual Import** tab is displayed. 9. In the **Manual Import** tab, click **Browse**, navigate to the file location, and select it. 10. Select the file and click **Import**. A pop-up opens giving you the status of the upload. 11. After the upload is complete, go to **Devices** → **** → **Devices** → **** → **Deploy Pending Changes**. In the **Deploy Pending Changes** page, the **Pending Changes** column displays **New Gateway Anti-Malware Versions**. 12. Select the check-box for **GAM Updates** and click **Deploy**. ## Results A pop-up window appears showing you the status of the update. Upon successful deployment, click **Close** in the pop-up window. > [!NOTE] > Note > > If the update fails, it is likely that you have downloaded an incompatible version. Review the compatible versions and the combinations listed in the Gateway Anti-Malware engine compatibility matrix table to ascertain if you have downloaded the appropriate version. There is an alternate way to deploy the GAM update file to your Sensor from the **Device Manager** page. To deploy: 1. Navigate to **Devices** → **** → **Global** → **Device Manager** and select **Sensors** tab. The **Sensors** tab is displayed listing all the attached Sensors. 2. Select the compatible Sensor on which you want to deploy the GAM update file, and click **Sync**. Select Sensor to synchronize GAM Updates ![](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/GUID-940CCC54-AD62-49F7-965F-F2A15E9C17F7-low(1).png?sv=2026-02-06&spr=https&st=2026-11-20T06%3A53%3A55Z&se=2026-11-20T07%3A53%3A55Z&sr=c&sp=r&sig=XodtJCd2Dx9Pbpjq3t2c%2B5rr6eMMKhbD1gClU0VR94U%3D) 3. The **Sync: ** window is displayed with **GAM Updates** check-box selected. If there are any other pending deployments, the respective check-boxes will also be selected by default. You may uncheck any of them if you want to skip their deployment. > [!NOTE] > Note > > The Manager provides an option to concurrently deploy pending changes onto multiple Sensors. When you select multiple Sensors for deployment, a **Bulk Sync** window is displayed with all check-boxes selected by default. You may uncheck any of them if you want to skip their deployment. 4. Click **Sync** to begin the deployment. GAM Updates selected for synchronization ![](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/GUID-368E1AE8-C01E-43B6-880B-CD282C6040BF-low(1).png?sv=2026-02-06&spr=https&st=2026-11-20T06%3A53%3A55Z&se=2026-11-20T07%3A53%3A55Z&sr=c&sp=r&sig=XodtJCd2Dx9Pbpjq3t2c%2B5rr6eMMKhbD1gClU0VR94U%3D) 5. A **Deployment Details** dialog-box is displayed, click ![](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/GUID-16F4A5CB-64F8-49D7-9C0D-A9BB21DAA8A6-low.png?sv=2026-02-06&spr=https&st=2026-11-20T06%3A53%3A55Z&se=2026-11-20T07%3A53%3A55Z&sr=c&sp=r&sig=XodtJCd2Dx9Pbpjq3t2c%2B5rr6eMMKhbD1gClU0VR94U%3D). Deployment Details ![](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/GUID-B3B5892E-D545-4354-94AE-8DCD033234F6-low.png?sv=2026-02-06&spr=https&st=2026-11-20T06%3A53%3A55Z&se=2026-11-20T07%3A53%3A55Z&sr=c&sp=r&sig=XodtJCd2Dx9Pbpjq3t2c%2B5rr6eMMKhbD1gClU0VR94U%3D) 6. You may click the ![](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/GUID-62A0322B-15AF-4A6C-9D83-839F63FF07E1-low.png?sv=2026-02-06&spr=https&st=2026-11-20T06%3A53%3A55Z&se=2026-11-20T07%3A53%3A55Z&sr=c&sp=r&sig=XodtJCd2Dx9Pbpjq3t2c%2B5rr6eMMKhbD1gClU0VR94U%3D) icon to refresh the **Sensors** tab and view the latest Sync status. Upon successful deployment, the status is displayed as **Synchronized**, and the deployed version of GAM is displayed under the **Protections** column. > [!NOTE] > Note > > You can also view the deployment status in **Manager** → **** → **Troubleshooting** → **Logs** under the **Background Tasks** tab. The status is displayed as **In Progress** during the deployment and **Complete** upon successful deployment. You need to refresh the tab to view the latest deployment status. > [!NOTE] > Note > > If the Sync fails, it is likely that you have downloaded an incompatible GAM version. Review the compatible versions and the combinations listed in the Gateway Anti-Malware engine compatibility matrix table to ascertain if you have downloaded the appropriate version.