--- title: "Update software for offline devices" slug: "update-software-for-offline-devices" tags: ["Install and Get Started", "IPS 10.1.10"] updated: 2026-09-23T09:38:58Z published: 2026-09-23T09:38:58Z canonical: "docs.trellix.com/update-software-for-offline-devices" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Update software for offline devices Follow this procedure for updating device configuration for offline devices: ## Task 1. Go to **Devices** → **** → **Global** → **Device Manager**. The **Device Manager** page is displayed. ![](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/GUID-7BC72398-2EA2-49AD-9DEA-4F9EDD4860C9-low.jpg?sv=2026-02-06&spr=https&st=2026-11-20T05%3A49%3A43Z&se=2026-11-20T06%3A49%3A43Z&sr=c&sp=r&sig=rgIXI1w4nTj%2BdyRTr9rHdiPl16911GN3gl6tB%2FUxUfU%3D) 2. Select the **Sensors** tab. From the list of Sensors, select the required Sensor. 3. Select **Export Sync File** from the **Other Actions** drop-down. 4. Save the device image upgrade file to the location of your choice. 5. Copy the device configuration file to the TFTP server. 6. Connect to the device through CLI and configure the TFTP server IP. 7. Execute the loadconfiguration <image filepath in the tftp server><imagefile name> from the CLI. 8. Once the image file copied on to the device (it takes some time), check with downloadstatus command in the CLI to get the status. 9. Reboot the device on successful loading of the image. > [!NOTE] > Note > > You can perform Sensor reboot by clicking **Reboot** from **Other Actions** drop-down.