--- title: "Updating managed appliances using the Web UI" slug: "updating-managed-appliances-using-the-web-ui-2" updated: 2026-08-25T21:18:10Z published: 2026-08-25T21:18:10Z canonical: "docs.trellix.com/updating-managed-appliances-using-the-web-ui-2" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Updating managed appliances using the Web UI Use the appliance update page to determine whether the latest appliance system image and guest images are installed, and to update them as needed. You can also use this page to view the installed security content version. ### Note You can perform this procedure whether the managed appliance uses **CMS**, **CDN**, or **DTI** as its DTI source server. (See [Changing the active setting for a DTI service](/docs/changing-the-active-setting-for-a-dti-service-3) for details about these options.) ![CM_ApplianceUpdates_scap.PNG](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-eec44fb6-0b90-0fcb-7cbe-e4a5ce5c35b5.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A25%3A39Z&se=2026-11-20T05%3A25%3A39Z&sr=c&sp=r&sig=iV07YY59oZJtap9tyGBNTvRFlH7cNnHFkVFgU%2FAAm70%3D) This page contains the information described in the following table. | Field | Description | | --- | --- | | **Sensor(hostname)** | The display name of the appliance. | | **Connection** | The status of the connection between the Central Management System appliance and the managed appliance. \| ![CM_EstablishedConnection_icon.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-48d2931d-d43c-57c3-9231-0183d3b2950d.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A25%3A39Z&se=2026-11-20T05%3A25%3A39Z&sr=c&sp=r&sig=iV07YY59oZJtap9tyGBNTvRFlH7cNnHFkVFgU%2FAAm70%3D) \| The connection is established. \| \| --- \| --- \| \| ![CM_ConnectionFailure_icon.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-eab3ec73-01fd-65b6-916e-be55a57cbfee.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A25%3A39Z&se=2026-11-20T05%3A25%3A39Z&sr=c&sp=r&sig=iV07YY59oZJtap9tyGBNTvRFlH7cNnHFkVFgU%2FAAm70%3D) \| The connection failed; the appliance cannot be updated until the connection is reestablished. \| | | ![CM_EstablishedConnection_icon.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-48d2931d-d43c-57c3-9231-0183d3b2950d.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A25%3A39Z&se=2026-11-20T05%3A25%3A39Z&sr=c&sp=r&sig=iV07YY59oZJtap9tyGBNTvRFlH7cNnHFkVFgU%2FAAm70%3D) | The connection is established. | | ![CM_ConnectionFailure_icon.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-eab3ec73-01fd-65b6-916e-be55a57cbfee.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A25%3A39Z&se=2026-11-20T05%3A25%3A39Z&sr=c&sp=r&sig=iV07YY59oZJtap9tyGBNTvRFlH7cNnHFkVFgU%2FAAm70%3D) | The connection failed; the appliance cannot be updated until the connection is reestablished. | | **Product** | The type of appliance. | | **System Software Status** | The installed appliance software version. If other versions are available, you can select a version or select **none** to do this later. | | **Detection Engine Status** | Whether the latest guest images are installed. If not, you can select **latest** to install them or select **none** to do this later. **NOTE:** This column is empty for an appliance in MVX sensor mode. | | **Sensor Update Status Info** | Indicators and information about current and available versions or the update being performed. \| ![CM_EstablishedConnection_icon.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-48d2931d-d43c-57c3-9231-0183d3b2950d.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A25%3A39Z&se=2026-11-20T05%3A25%3A39Z&sr=c&sp=r&sig=iV07YY59oZJtap9tyGBNTvRFlH7cNnHFkVFgU%2FAAm70%3D) \| All available guest images and patches have been updated. \| \| --- \| --- \| \| ![CM_ConnectionFailure_icon.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-eab3ec73-01fd-65b6-916e-be55a57cbfee.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A25%3A39Z&se=2026-11-20T05%3A25%3A39Z&sr=c&sp=r&sig=iV07YY59oZJtap9tyGBNTvRFlH7cNnHFkVFgU%2FAAm70%3D) \| An error occurred, such as the update timing out. \| \| ![CM_UpdatesAvailable_icon.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-df494961-5b31-3eee-3c63-0a55554b4b89.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A25%3A39Z&se=2026-11-20T05%3A25%3A39Z&sr=c&sp=r&sig=iV07YY59oZJtap9tyGBNTvRFlH7cNnHFkVFgU%2FAAm70%3D) \| New updates are available. \| \| ![CM_UnsupportedVersion_icon.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-b73c0b2b-0ab6-e0f2-5096-87983cc773e1.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A25%3A39Z&se=2026-11-20T05%3A25%3A39Z&sr=c&sp=r&sig=iV07YY59oZJtap9tyGBNTvRFlH7cNnHFkVFgU%2FAAm70%3D) \| The installed appliance software version is not supported by the Central Management System appliance. \| \| ![03000048.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-88f39031-2046-f1b3-ad27-e7b2316fb35d.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A25%3A39Z&se=2026-11-20T05%3A25%3A39Z&sr=c&sp=r&sig=iV07YY59oZJtap9tyGBNTvRFlH7cNnHFkVFgU%2FAAm70%3D) \| An immediate reload is required to complete the upgrade. \| | | ![CM_EstablishedConnection_icon.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-48d2931d-d43c-57c3-9231-0183d3b2950d.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A25%3A39Z&se=2026-11-20T05%3A25%3A39Z&sr=c&sp=r&sig=iV07YY59oZJtap9tyGBNTvRFlH7cNnHFkVFgU%2FAAm70%3D) | All available guest images and patches have been updated. | | ![CM_ConnectionFailure_icon.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-eab3ec73-01fd-65b6-916e-be55a57cbfee.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A25%3A39Z&se=2026-11-20T05%3A25%3A39Z&sr=c&sp=r&sig=iV07YY59oZJtap9tyGBNTvRFlH7cNnHFkVFgU%2FAAm70%3D) | An error occurred, such as the update timing out. | | ![CM_UpdatesAvailable_icon.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-df494961-5b31-3eee-3c63-0a55554b4b89.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A25%3A39Z&se=2026-11-20T05%3A25%3A39Z&sr=c&sp=r&sig=iV07YY59oZJtap9tyGBNTvRFlH7cNnHFkVFgU%2FAAm70%3D) | New updates are available. | | ![CM_UnsupportedVersion_icon.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-b73c0b2b-0ab6-e0f2-5096-87983cc773e1.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A25%3A39Z&se=2026-11-20T05%3A25%3A39Z&sr=c&sp=r&sig=iV07YY59oZJtap9tyGBNTvRFlH7cNnHFkVFgU%2FAAm70%3D) | The installed appliance software version is not supported by the Central Management System appliance. | | ![03000048.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-88f39031-2046-f1b3-ad27-e7b2316fb35d.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A25%3A39Z&se=2026-11-20T05%3A25%3A39Z&sr=c&sp=r&sig=iV07YY59oZJtap9tyGBNTvRFlH7cNnHFkVFgU%2FAAm70%3D) | An immediate reload is required to complete the upgrade. | If updates are available for an appliance, the checkbox in the **Sensor (hostname)** column can be selected, and a message is displayed in the column. For example: ![CM_NewUpdates_icon.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-9af3bc1a-2c8b-cadb-9297-b9648f3fcba0.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A25%3A39Z&se=2026-11-20T05%3A25%3A39Z&sr=c&sp=r&sig=iV07YY59oZJtap9tyGBNTvRFlH7cNnHFkVFgU%2FAAm70%3D)![CM_Unsupported_icon.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-5cae8099-df6f-84c8-8f7a-91d81558b0cd.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A25%3A39Z&se=2026-11-20T05%3A25%3A39Z&sr=c&sp=r&sig=iV07YY59oZJtap9tyGBNTvRFlH7cNnHFkVFgU%2FAAm70%3D)To update an appliance: 1. Click the **Appliances** tab. The **Sensors** tab should be selected. 2. On the **Sensors** page, click **Actions** > **Update Sensors**. 3. If you want to filter by appliance group, select the group in the **Sensor Group** drop-down list. 4. Select the checkbox for each appliance you want to update. 5. (Optional) To select all the managed appliances for an upgrade, select **All** in the **Sensor Group** dropdown menu. 6. To update the system image: 1. Select the version from the drop-down list in the **System Software Status** column. For example: ![CM_SWVersionUpdate_scap.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-52d0df04-c146-d418-9d8c-0c044c525152.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A25%3A39Z&se=2026-11-20T05%3A25%3A39Z&sr=c&sp=r&sig=iV07YY59oZJtap9tyGBNTvRFlH7cNnHFkVFgU%2FAAm70%3D) If you want to postpone this update, select **none**. 2. The appliance must be rebooted after the upgrade. If you want this to happen automatically, select the **Auto Reboot** checkbox. 7. If the guest images need to be updated, select **latest** in the **Detection Engine Status** column. (If you want to postpone this update, select **none**.) ### Note Appliances in MVX sensor mode do not have guest images, so the **Detection Engine Status** column is empty. 8. Click **Update Selected Sensors**. Status messages will be displayed in the **Sensor Update Status Info** column. For example: ![CM_Transfer_icon.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-dabc2c9d-0bbd-cdc0-7bda-10646feb5e32.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A25%3A39Z&se=2026-11-20T05%3A25%3A39Z&sr=c&sp=r&sig=iV07YY59oZJtap9tyGBNTvRFlH7cNnHFkVFgU%2FAAm70%3D) 9. If you did not select **auto reboot**, the following message is displayed after the update is done: ![CM_Reload_icon.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-b5e0e983-1ea9-291b-5b5e-0236ec1d2f36.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A25%3A39Z&se=2026-11-20T05%3A25%3A39Z&sr=c&sp=r&sig=iV07YY59oZJtap9tyGBNTvRFlH7cNnHFkVFgU%2FAAm70%3D) Click the **Reload** checkbox, and then click **OK** when prompted to confirm the action. ![CM_Reload_scap.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-ebf180bc-5b18-7072-7470-db8965e3f438.png?sv=2026-02-06&spr=https&st=2026-11-20T04%3A25%3A39Z&se=2026-11-20T05%3A25%3A39Z&sr=c&sp=r&sig=iV07YY59oZJtap9tyGBNTvRFlH7cNnHFkVFgU%2FAAm70%3D) :