--- title: "Upgrade the Software on Device" slug: "upgrade-the-software-on-device" tags: ["Reference", "IPS 10.1.10"] updated: 2026-09-23T09:37:28Z published: 2026-09-23T09:37:28Z canonical: "docs.trellix.com/upgrade-the-software-on-device" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Upgrade the Software on Device This URL upgrades the software on device. ## Resource URL PUT sensor//deploydevicesoftware/ ## Request Parameters URL Parameter | Field Name | Description | Data Type | Mandatory | | --- | --- | --- | --- | | sensor_id | Sensor ID | Number | Yes | | swVersion | Software version to upgrade | String | Yes | ## Response Parameters Following fields are returned if the request parameters are correct, otherwise error details are returned. | Field Name | Description | Data Type | | --- | --- | --- | | RequestId | The ID of the upgrade process | String | ## Example **Request** PUT [https:///sdkapi/sensor/1001/deploydevicesoftware/9.1.5.9](https://%3CNSM_IP%3E/sdkapi/sensor/0/ntbaintegration) **Response** ``` { "RequestId": "1337547887180" } ```   ## Error Information Following error codes are returned by this URL: | S.No | HTTP Error Code | SDK API errorId | SDK API errorMessage | | --- | --- | --- | --- | | 1 | 400 | 1106 | Invalid Sensor ID | | 2 | 400 | 3010 | Software version provided does not exist for the Sensor : (:) |