--- title: "Verify successful installation" slug: "verify-successful-installation-1" tags: ["Hardware", "IPS 11.1.x"] updated: 2026-09-17T11:10:21Z published: 2026-09-17T11:10:21Z canonical: "docs.trellix.com/verify-successful-installation-1" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Verify successful installation 1. Type `status` in the Sensor CLI. The status report appears. ![GUID-33EC5529-DD98-4F8F-B5A0-773ECC78F47B-low.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-d5649914-bef7-1d95-f0d7-f1bf89c8ccf6(1).png?sv=2026-02-06&spr=https&st=2026-11-20T08%3A50%3A20Z&se=2026-11-20T09%3A50%3A20Z&sr=c&sp=r&sig=u7ktQPxK78Gy2KCjfC2w1rXzInooQt069R6wIfuz7dg%3D) The Sensor parameter `System Initialized` should be `yes`, and for Manager communication `Trust Established` should be `yes`. 2. From the Manager **Dashboard**, view the Manager status in the **System Faults** monitor. The Manager status displays as **Up** and Sensor status is **Active**. ![GUID-695B1800-763F-4EB9-9287-85C07A2AF7CA-low.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-bd700b52-5e22-2fdb-4415-877a7677c4f3.png?sv=2026-02-06&spr=https&st=2026-11-20T08%3A50%3A20Z&se=2026-11-20T09%3A50%3A20Z&sr=c&sp=r&sig=u7ktQPxK78Gy2KCjfC2w1rXzInooQt069R6wIfuz7dg%3D) 3. From the Manager, click **Devices** → **** → **Devices** → **Setup** → **Physical Ports** to view the port details of the standalone Sensor. ![GUID-905DE33E-0B2B-4E43-9F9D-0AAF36C41C1C-low.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-332c34b8-321b-b685-26a3-2713dbd3cb88.png?sv=2026-02-06&spr=https&st=2026-11-20T08%3A50%3A20Z&se=2026-11-20T09%3A50%3A20Z&sr=c&sp=r&sig=u7ktQPxK78Gy2KCjfC2w1rXzInooQt069R6wIfuz7dg%3D) Click **Devices** → **** → **Devices** → **** → **Member Sensors** → **** → **Setup** → **Physical Ports** to view the port details of a Sensor in a stack. ![GUID-6DFD0C4E-B457-41F8-AE82-35A9F3CF9E16-low.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-8450ca8d-e469-3e23-2943-fc8b46e500a6.png?sv=2026-02-06&spr=https&st=2026-11-20T08%3A50%3A20Z&se=2026-11-20T09%3A50%3A20Z&sr=c&sp=r&sig=u7ktQPxK78Gy2KCjfC2w1rXzInooQt069R6wIfuz7dg%3D) 4. A policy named **Default Prevention** is active upon the addition of the Sensor. To view this policy, select **Policy** → **** → **Intrusion Prevention** → **Policy Types** → **IPS Policies**. The **Default Prevention** policy contains attacks already configured with a "blocking" Sensor response action. If any attack in the policy is triggered, the Sensor automatically blocks the attack. To tune this or any other Trellix-provided policies, you can clone the policy and then customize it as described in Trellix Intrusion Prevention System Product Guide. 5. Click **Devices** → **** → **Devices** → **Setup** → **Physical Ports**. 6. To view port settings, select the port on the Sensor that you cabled. Ensure that your port settings match the cabling. For example, if port 1 is cabled for inline mode, the mode of operation in the port setting should be inline mode. > [!NOTE] > Note > > For more information on port settings, see the chapter Configuring the monitoring and response ports of a Sensor in Trellix Intrusion Prevention System Product Guide.