--- title: "Verify your installation" slug: "verify-your-installation" tags: ["Hardware", "IPS 11.1.x"] updated: 2026-09-17T07:33:43Z published: 2026-09-17T07:33:43Z canonical: "docs.trellix.com/verify-your-installation" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # Verify your installation Follow these steps to make sure your setup is working as designed. **Steps:** 1. Check the icons in the Manager beside the ports you have configured as in-line fail-open passive. They must show **Up**. 2. Check the **Bypass** LED on the Sensor. | LED status | Description | | --- | --- | | ON | The Sensor is in inline fail-open, inline fail-closed, SPAN, or TAP mode. | | OFF | The Sensor is in bypass mode. | 3. Check the **PWR** LEDs on the chassis. Depending on which power source you use, you will see that **PWR** LED glowing. 4. Check the port status and operating mode status of the GE in-line fail-open ports. The picture below (to the left) shows you the fail-open switch in normal mode when the Sensor ports are operating normally. When the Sensor ports have gone down, the fail-open switch is seen in bypass mode as depicted the picture below (to the right). | ![GUID-CDD558FC-11C2-4B0C-BBB8-373168A03D9C-low.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-0152d99f-cd7d-3d02-3a53-da4bb5abcd99.png?sv=2026-02-06&spr=https&st=2026-11-20T17%3A33%3A11Z&se=2026-11-20T18%3A33%3A11Z&sr=c&sp=r&sig=x4HQLngyidjSq5jPXBe9JOAF8jcWF7E26FgHOFxmSTs%3D) | ![GUID-1A7C432C-8FC2-462C-B35E-43F6205FB5A5-low.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-429f54bb-138e-b837-24cd-f9603b89ecca.png?sv=2026-02-06&spr=https&st=2026-11-20T17%3A33%3A11Z&se=2026-11-20T18%3A33%3A11Z&sr=c&sp=r&sig=x4HQLngyidjSq5jPXBe9JOAF8jcWF7E26FgHOFxmSTs%3D) | | --- | --- | | Item | Description | | --- | --- | | NRM | Glows green when the Sensor is in normal mode of operation | | WDT | Indicates watchdog timer. The **Watch Dog Timer** LED always blinks amber, whether the fail-open switch is in normal or bypass mode. The blink indicates that the heartbeat pulse is being sent through the fail-open connection. The watchdog timer is always blinking, even when the fail-open switch is bypassing the Sensor because it is always sending and listening for the correct heartbeat state from the Sensor monitoring ports. | | BYP | Glows red when the fail-open switch is in a bypass mode of operation |