--- title: "What happens when a Sensor fails?" slug: "what-happens-when-a-sensor-fails-1" tags: ["Hardware", "IPS 11.1.x"] updated: 2026-09-17T07:33:43Z published: 2026-09-17T07:33:43Z canonical: "docs.trellix.com/what-happens-when-a-sensor-fails-1" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # What happens when a Sensor fails? When a Sensor fails with a Fail-Open module in place, the following events occur in the stated order: - The Manager reports a **Sensor in bad health** or a **Port pair is in bypass mode** error in the **System Health** page. - The Sensor reboots and the Fail-Open module begins forwarding traffic. All traffic now bypasses the Sensor and flows through the Fail-Open module with minimal traffic disruption (within milliseconds). - Upon reboot completion, the Sensor resumes its heartbeat, and one of the following occurs: - If the reboot occurred during normal operation as described, the Fail-Open module resumes passing data through the Sensor and the Sensor returns to Inline Fail-Open mode. - If the reboot occurred due to an error, the Fail-Open module continues to bypass the Sensor until the administrator manually re-enables Sensor ports in the Manager. After the ports are re-enabled, the Fail-Open module resumes passing data through the Sensor and the Sensor returns to in-line mode. - The errors on the Manager disappear and normal health is reported.