--- title: "What's new" slug: "what-s-new-11" tags: ["Release Notes", "IPS 11.1.x"] updated: 2026-10-01T07:59:03Z published: 2026-10-01T07:59:03Z canonical: "docs.trellix.com/what-s-new-11" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.trellix.com/llms.txt > Use this file to discover all available pages before exploring further. # What's new The primary objective of this firmware release is to identify transceivers that have **FTLC9551** type under Part Number. Few of the transceivers having this part number have been identified as faulty and may possibly result in link failure. Refer to the table [Transceiver Part Numbers and Serial Numbers](/network-and-platform/docs/transceiver-part-numbers-and-serial-numbers) for the list of Part Numbers and Serial Numbers associated with the transceivers that are found to be malfunctioning. > [!NOTE] > Note > > Please contact **Trellix Support** if the AFO module contains transceivers with these Part Numbers and Serial Numbers. You can view the Transceiver Part Numbers and Transceiver Serial Numbers in two ways: - **Viewing through the web interface:** 1. To access the 100G Active Fail-Open chassis web interface, enter the IPv4 address of the chassis in a web browser. 2. Go to **Status** → **Module **. > [!NOTE] > Note > > View information from both **Module 1** and **Module 2**. ![GUID-8F360335-77E7-48E0-B7BA-101DE7F0B325-low.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-4dfc56d1-0f8e-e2a4-916d-734aa7c4980e.png?sv=2026-02-06&spr=https&st=2026-11-20T18%3A09%3A20Z&se=2026-11-20T19%3A09%3A20Z&sr=c&sp=r&sig=zRZseUASGjF3OrFNEM5ZOsdS5qOCihIxSM4GLSFl8N4%3D) 3. In the **Module Information** window, scroll down to the **Port Transceiver Information** section. The Transceiver Part Numbers and Serial Numbers can be seen under the **TransceiverPN** and **TransceiverSN** columns respectively. ![GUID-F760D778-60FE-4EDA-8926-1E22038C27AF-low.png](https://cdn.us.document360.io/0d453a50-e1da-4d4a-9409-fea7959614d8/Images/Documentation/uuid-d0b9ce61-2917-140d-f70f-e1f5127cf5b3.png?sv=2026-02-06&spr=https&st=2026-11-20T18%3A09%3A20Z&se=2026-11-20T19%3A09%3A20Z&sr=c&sp=r&sig=zRZseUASGjF3OrFNEM5ZOsdS5qOCihIxSM4GLSFl8N4%3D) > [!NOTE] > Note > > Contact **Trellix Support** if the numbers match with those listed in [Transceiver Part Numbers and Serial Numbers](/network-and-platform/docs/transceiver-part-numbers-and-serial-numbers). - **Viewing through the CLI:** 1. Login to the CLI console of the 100G Active Fail-Open kit. 2. Issue `enable` command in the terminal to enter **Enable** mode. 3. Enter `show afo state` in the terminal. The transceiver port and serial numbers associated with each transceiver can be found under the **Port transceiver information** section under the **TransceiverPN** and **TransceiverSN** columns. ```plaintext IS100G_AFO> enableIS100G_AFO# show afo stateModule 1 Status:Type                  : IAC-2P100FOSR-KITSerialNumber          : N/ATrackingNumber        : N/AFirmware              : IS100G_AFO_MOD_1.0Speed                 : 100GMedia                 : 100GBase-SR4Transceiver           : QSFP28 SR4Segment 1.1 Status:HbChecking            : onHbCheckingOffReason   : noneApplicationState      : activeActiveState           : inlinePassiveState          : inlineTwoPortLinkTriggered  : noRX/TX Error Occurred  : yesPortNet0Link          : upPortNet1Link          : upPortMon0Link          : upPortMon1Link          : upPortNet0Health        : normalPortNet1Health        : normalPortMon0Health        : normalPortMon1Health        : normalSegmentSpeed          : 100GPort transceiver information:Name        TransceiverPN           TransceiverSNnet0        FTLC9551REPM            XXF0G86net1        FTLC9551REPM            XXF0CM1mon0        AFBR-89CDDZ-CS1         AVF2111G1JEmon1        FTLC9551REPM            X0SAGXMModule 2 Status:Type                  : IAC-2P100FOSR-KITSerialNumber          : T0B7932005TrackingNumber        : E135361100011Firmware              : IS100G_AFO_MOD_1.0Speed                 : 100GMedia                 : 100GBase-SR4Transceiver           : QSFP28 SR4Segment 2.1 Status:HbChecking            : onHbCheckingOffReason   : noneApplicationState      : activeActiveState           : inlinePassiveState          : inlineTwoPortLinkTriggered  : noRX/TX Error Occurred  : noPortNet0Link          : upPortNet1Link          : upPortMon0Link          : upPortMon1Link          : upPortNet0Health        : normalPortNet1Health        : normalPortMon0Health        : normalPortMon1Health        : normalSegmentSpeed          : 100GPort transceiver information:Name        TransceiverPN           TransceiverSNnet0        FTLC9551REPM            X0MAN8Rnet1        FTLC9551REPM            X0MAP03mon0        AFBR-89CDDZ-CS1         X0SAGYGmon1        FTLC9551REPM            XVD0B3R                           ``` > [!NOTE] > Note > > Contact **Trellix Support** if the numbers match with those listed in [Transceiver Part Numbers and Serial Numbers](/network-and-platform/docs/transceiver-part-numbers-and-serial-numbers).