The LEDs provide the status information of the server and the activity on its ports.

Power supply status LED

To indicate power supply status, there is a single bi-color LED. The LED operation is defined as:

Trellix ESM power supply indicator light states

Color

State

Status

Green

Solid

Power supply is ON

Blinking

Power supply is plugged in and turned off by the system.

Amber

Solid

Power supply is plugged in, and is in an abnormal state. The system might need service.

Blinking

Power supply continues to operate with warning events:

  • High temperature

  • High power

  • High current

  • Slow fan

Off

Off

No AC power to all power supplies



External RJ45 NIC Port LED

Each LAN has one bi-colored LED per port (RJ45 or SFP+) at the bottom of PCB. The LEDs indicates link speed.

LED Color

Description

Amber

The data rate is <12Gbps

Green

The data rate is 12Gbps

System Status LED

Indicate the current health of the server system.

Color

State

Description

Red

Solid on

An overheating condition has occurred

Red

Blinking at 1Hz

Fan failure, check the inoperative fan

Red

Blinking at 0.25Hz

Power failure, check the non-operational power supply

Red

Blinking at 10Hz

CPLD recovery mode error

Red

blinking at 10Hz and the rear UID LED is blue, blinking at 10Hz

CPLD recovery or update is in progress

Blue

Solid

Unit ID is activated by the switch

Blue

Blinking at 1Hz

Unit ID is activated by the BMC

Blue

Blinking at 2Hz, and BMC Heartbeat LED on the motherboard is green

BMC is resetting

Blue

Blinking at 4Hz

BMC is resetting factory defaults

Blue

Blinking at 10Hz

BIOS/BMC is recovering or updating

Drive Activity and Status LED

Each drive carrier includes separate LED indicators for drive Activity and drive Status.

Color

State

Behavior of device

Status LED

Off

Idle SATA drive installed

Blue

Solid on

Idle SAS drive installed

Blue

Blinking pattern

I/O activity

Condition

Drive Type

Behavior

Green

Turn on with no drive activity

SAS

LED stays on

SATA

LED stays off

Turn on with drive activity

SAS

LED blinks off when processing a command

SATA

LED blinks on when processing a command

Turn on and drive spun down

SAS

LED stays off

SATA

LED stays off

Turn on and drive spinning up

SAS

LED blinks

SATA

LED stays off

Power button

Toggles the system turn on and off.

LED

State

Description

Green

Solid

System power is on.

Green

Blinking at 4Hz

BMC/BIOS checking

Red

Blinking (2 blinks red) at 4Hz, 1 pause at 2Hz (on-on-off-off)

BMC recovery or update is in progress

Green

Blinking at 1Hz

BMC/BIOS flash not detected

BMC Boot or Reset Status LED indicators

A baseboard management controller (BMC) boot occurs when AC power is first applied to the system. A BMC reset occurs after a BMC FW update, on receiving a BMC cold command, and on a BMC watchdog initiated reset.

BMC Boot or Reset State

UID LED

State

Status LED

BMC reset

Blue

Blinks at 2Hz

Solid Green

Restore defaults

Blue

Blinks at 4Hz

Off

Update

Blue

Blinks at 10Hz

-