You must disable both ports required for port pair operation when changing the operating Mode from single port (SPAN or Hub) Mode to a port pair (Tap or Inline) mode. Device monitoring ports are configured by default to operate in SPAN or Hub mode.
Task
- Go to Devices → <Admin Domain Name> → Devices → <Device_Name> → Setup → Physical Ports.
- Double-click on the row of the port to be configured. The Monitoring Port Details panel is displayed on the right side.
- Select Disabled from the State drop-down list.
- Click Save.
- Select the peer port (for example, 1B).
- Select Disabled at the State drop-down list.
-
Select
Tap
or
Inline Fail Open mode as the
Mode.
Note
To configure from port pair mode to single port mode, select SPAN or Hub as the Mode.
- Click Enabled at State.
- Configure your port settings (port speed or Trellix certification, duplex, response port usage).
- Click Save.
- Select port 1A to verify the State reads Enabled and the Mode matches your new setting.
- Click Save.