You can access the command line interface through the console port (serial terminal emulator) and web-based management via a secure HTTPS connection on the management port (SSH remote shell emulator).
Steps:
Ensure that the chassis power is turned on.
Using an RJ45 RS232 console cable, connect a PC that is running the HyperTerminal to the Active Fail-Open Kit chassis.
Launch the HyperTerminal and set the following communication parameters.
Baud rate: 115200
Data bits: 8
Parity: None
Stop bits: 1
Flow Control: XON/XOFF
Click OK. The CLI banner and login prompt are displayed.
Note
The default Username and Password are Trellix00. The password is configurable.
Type the following:
Enable
Configure
management eth-if ip x.x.x.x
management eth-if ip-mask y.y.y.y
management eth-if default-gateway z.z.z.z
write memory
Note
Reboot of the system is not required.
To view the current network settings, use the following command:
show management configuredSample output:
IS100G_AFO> show management configuredInterface Configurations:MacAddr : 00:e0:ed:93:24:9fPort : upIPOrigin : staticIPAddress : 10.41.83.134IPMask : 255.255.255.0Default-Gateway : 10.41.83.252DHCPSendName : on