The new docs.trellix.com features a modernized UI and AI-powered conversational search. Content is currently available in English, with additional languages launching in early November 2026. We hope you enjoy the updated experience.

Configure Active Fail-Open kits 18 and 19

Prev Next

Prerequisites:

For each Active Fail-Open configuration, you will need to make sure you have all these components.

  • Determine the IP address for the Active Fail-Open switch or, if you are deploying multiple switches, a range of IP addresses

  • Determine a network mask and the default gateway for the Active Fail-Open switch

  • 4 cables to connect the Active Fail-Open switch and the Sensor

  • An RJ-45 RS232 cable to access the Active Fail-Open switch CLI

  • QSFP28 for NS9500 Sensors

  • Cables for a fiber Active Fail-Open switch:

    • LC and MTP/MPO fiber cables for network ports

    • LC and MTP/MPO fiber cables for monitor ports

Broadly, these are the steps you will need to follow to set up an Active Fail-Open kit.

Note

While configuring the 100G Active Fail-Open chassis, you must enable Forward Error Correction (FEC) in the AFO configuration. To enable FEC, go to AFO Configuration → Module <number> → Advanced Features and enable Net 0 FEC, Net 1 FEC, Mon 0 FEC, and Mon 1 FEC.