The new docs.trellix.com features a modernized UI and AI-powered conversational search. Content is currently available in English, with additional languages launching in early November 2026. We hope you enjoy the updated experience.

Inside the box

Prev Next

Every fail-open kit consists of the same set of components. Although the type of cables and the switch vary from one model to another, the list of items in the kit itself remains the same. The table provides you with a list of items.

Qty

Item

Description

1

Fail-Open switch

Copper: 1000Base-T switch; connects to the GE ports of all applicable Sensor models directly through the Sensor's built-in Control port

Fiber: Connects to the 1-Gigabit or 10-Gigabit ports of all applicable Sensor models directly through the Sensor's built-in Control port

1

19-inch rack-mount panel for 3 switches

1RU mounting hardware to mount up to 3 bypass switches in a standard rack

1

3 m RJ-45 to RJ-11 cable

Connects the Sensor Control port to the fail-open switch

4

Copper: 3 m RJ-45 to RJ-45 cable

Fiber: 3 m LC-LC

Connects the fail-open switch to network devices and the Sensor

Note

For a fiber fail-open kit, these cables are either single-mode or multi-mode cables depending on the requirements provided at the time of purchase.