These are the warning faults for a Sensor device.
Fault | Severity | Description/Cause | Action |
|---|---|---|---|
Device Startup Detected | Warning | The device has powered up or rebooted. | If the device rebooted, confirm that the reboot was intentional. If not, consult the system log for details. |
Voltage Error | Warning | Device voltage is outside its normal range | Ensure that all cables are connected correctly. Check connections on the fans and HDDs. Replace the CMOS battery. Remove all, but minimum components for operation and check sensor. If the issue follows a particular component, swap it, otherwise, replace the board. If the issue remains, replace the power supplies. |
Fan Error | Warning | Device fan is not performing at expected capacity | Swap the fans round to see whether the problem stays with the location or follows the fan. Replace the fan or fan wiring/housing depending on the previous outcome. If the system has been in this use for a while, the event may be a sign of impending fan failure. Replace the fan. |
Power Supply Error | Warning | Device power supply is outside its normal range | Remove and reapply AC. If the power supply still fails, replace it. |
Processor Error | Warning | Device processor error | Internal Error: Swap processors and test. Replace the processors depending on the results of the test. Thermal Issues: Verify heatsink is properly attached and has thermal grease. If the system has a heatsink fan, ensure the fan is spinning. Check all system fans are operating properly. Check that the air used to cool the system is within limits. |
Memory Error | Warning | Device memory error |
|
Physical Security Error | Warning | Device physical security error | Chassis intrusion: Use the Quick Start Guide and the Service Guide to determine whether the chassis intrusion switch is connected properly. If this is the case, make sure it makes proper contact when the chassis is closed. LAN Leash lost: Could be most likely due to unplugging the cable but can also happen if there is an issue with the cable or switch. Check the LAN cable and connector for issues. Investigate switch logs where possible. If this is also the case, someone has opened the chassis. Ensure nobody has access to the system that should not. |
Physical Interrupt Error | Warning | Physical Interrupt error. | PCI related Issue:
|
FP (NMI) Interrupt (Frontend Panel Non-Maskable Interrupt) |
| ||
System Firmware Error | Warning | Device system firmware error | If this is a serious error, there is typically also a corresponding System Event Log entry logged for whatever was the cause of the error; this event may contain more information about what happened. |
Watchdog Error | Warning | Device watchdog error | Capture a System BMC Debug Log as soon as possible after the failure. OS event logs need to be investigated to determine what may have caused this. |
Logging Error | Warning | Device logging disabled error | The BMC logs an SEL clear event. This is an informational event only. This is only ever the first event in the SEL. The cause of this event is either a manual SEL clear or some other IPMI-aware utility or is done in the factory as one of the last steps in the manufacturing process. |
Generic Hardware Error | Warning | Device General Hardware error | Caused by another event. System event logs would be cleared manually. Platform event Filters were triggered to send alerts of system event logs. Inspect system event logs that are found around the time of event. |
Operating System Shutdown Error | Warning | Operating system shutdown error | These events are usually found along with several other events. Examine System event log entries found around the event timestamp. Events come along with reason code. Refer Intel SEL troubleshooting guide to decode them. |
Sensor Health Changed | Warning | Health of sensor {0} changed from {1} to {2} | Please visit Devices → Sensor Health → Health Status to more about the health of the sensor |
HA Peer Status Change | Warning | High-availability device {0} is {1} | A status of Incompatible indicates that the HA member Sensors are not running the same Sensor software version, which is required for proper HA function. A status of Down indicates that the peer Sensor cannot be reached. In this case, check the HA interconnect port's status as well as the peer Sensor's health. |
Device Reboot Required | Warning | The jumbo frame parsing setting on this device has been updated and a reboot is required for the change to take effect. | Reboot the device to make the change take effect. |
Pluggable Interface Certification Status | Warning | Pluggable interface in port {0} is {1} | Replace the non-certified transceiver with a Trellix-certified one or update the physical port's settings to allow a non-certified connector type. |
Device performance - {0} | Warning | {0}{1} {2} detected on {3}. ({4} Threshold: {5}{6}). | Review the number and duration of performance-related faults for this device and refer its performance charts to determine if high usage is an on-going occurrence. If yes, a model with a higher system capacity should be considered. (Tip: Multiple capacities are supported on some models with a license change to increase the capacity) |
Alert Channel Down | Warning | The alert channel for device {0} is down, but the physical link is up. Details: {1} | The device normally auto recovers from this issue. If your device is otherwise behaving normally, you can ignore this message. |
Device Configuration Change Detected | Warning | A change in the physical configuration for device {0} has been detected. A new configuration has been discovered. | Refer the physical ports and confirm if the configuration change is intended. |
Failed to Dismantle HA Pair | Warning | The HA pair could not be dismantled as device {0} is disconnected from the Manager. (The Manager will try to dismantle once the device reconnects.) | Ensure that both member devices in the HA pair are connected to the Manager. |
HA pair Configuration Out-of-Sync | Warning | Pending changes could not be deployed to the device {0} in a HA pair {1}. Configuration will be out-of-sync until pending changes are deployed to both devices in the pair. (The Manager will continue to deploy changes until the deployment is successful.) | Ensure that the device is connected to the Manager and is in good health. |
HA pair Configuration Out-of-Sync | Warning | The firewall connection status for the devices in the HA pair {0} is inconsistent. This results in inconsistent functioning of firewall in the pair. | Ensure that both devices in a HA pair are connected to the firewall and the devices are online in good health. |
HA Pair Decryption Certificates Out-of-Sync | Warning | SSL decryption certificates could not be deployed to device {0} in HA pair {1}. The certificates will be out-of-sync until they are deployed to both devices in the pair. (The Manager will continue to attempt to deploy them until deployment is successful.) | Ensure that the device is connected to the Manager and in good health. |
Callback Detectors Out-of-Sync | Warning | The deployment of Callback Detectors to the device {0} failed. The Callback Detectors on the HA pair {1} are out-of-sync as a result. (The Manager will automatically make another attempt to deploy them.) | Ensure that the device is connected to the Manager and in good health. |
Device Discovered with Expiring License | Warning | Device {1} was discovered with a license that will expire on {0}. | Renew the expiring license. |
Pending Device License Expiration | Warning | Device {0} ({1}) license expires in less than {2} days. | Renew the expiring license. |
Pending Device Support License Expiration | Warning | Device {0} (support {1}) license expires in less than {2} days. | Renew the expiring license. |
Pending Device Add-On License Expiration | Warning | Device {0} (device {1}) license expires in less than {2} days. | Renew the expiring license. |
Pending Device Support Add-On License Expiration | Warning | Device {0} (support {1}) license expired in less than {2} days. | Renew the expiring license. |
License Detected for {0} of Type {1} | Warning | License valid until {0}. | Renew the license before it expires. |
Pending License Expiration for {0} of Type {1} | Warning | License for this device expires in {0} days. | Renew the license. |
Expiring License | Warning | The SSL proxy decryption license key {0} will expire on {1}. Updates to the Sensor to which it is assigned will be prevented once the license has expired. License details - Model:{2}, Capacity:{3}, Required Devices:{4}, Grant ID:{5}, Customer Name:{6}, Expiration:{7}, Assigned To:{8} | Renew the license. |
Expiring License | Warning | The SSL proxy decryption license key {0} will expire on {1}. License details - Model:{2}, Capacity:{3}, Required Devices:{4}, Grant ID:{5}, Customer Name:{6}, Expiration:{7}, Assigned To:{8} | Renew the license. |
Expired License | Warning | Proxy Decryption License with key {0} has expired. License details - Model:{1}, Capacity:{2}, Required Devices:{3}, Grant ID:{4}, Customer Name:{5}, Expiration:{6}, Assigned To:{7} | Replace the expired license with a valid one. |
System License Required | Warning | Sensor {0}, which was added to admin domain {1}, is running without a valid system license. Updates to the Sensor will be prevented until a valid license is assigned. | Assign the device a valid system license. |
Expired License | Warning | The system license with key {0} has expired and 30 days passed beyond expiry. License details - Model:{1}, Capacity:{2}, Required Devices:{3}, Grant ID:{4}, Customer Name:{5}, Expiration:{6}, Assigned To:{7} | Replace the expired license with a valid one. |
Expired License | Warning | The system license with key {0} has expired. Post 30 days of expiry the license cannot be used. License details - Model:{1}, Capacity:{2}, Required Devices:{3}, Grant ID:{4}, Customer Name:{5}, Expiration:{6}, Assigned To:{7} | Replace the expired license with a valid one. |
Expired License | Warning | The evaluation system license with key {0} has expired. License details - Model:{1}, Capacity:{2}, Required Devices:{3}, Grant ID:{4}, Customer Name:{5}, Expiration:{6}, Assigned To:{7} | Replace the expired license with a valid one. |
Expiring License | Warning | The system License with key {0} will expire on {1}. Post 30 days of expiry, license cannot be used. License details - Model:{2}, Capacity:{3}, Required Devices:{4}, Grant ID:{5}, Customer Name:{6}, Expiration:{7}, Assigned To:{8} | Renew the license. |
Expiring License | Warning | The system License with key {0} will expire on {1}. Post 30 days of expiry, updates to the Sensor to which it is assigned will be prevented. License details - Model:{2}, Capacity:{3}, Required Devices:{4}, Grant ID:{5}, Customer Name:{6}, Expiration:{7}, Assigned To:{8} | Renew the license. |
Console Login Failure | Warning | {3} login failure threshold of 3 attempts is exceeded for user name {0} from remote IP Address {1} on remote port {2}. | |
Device Packet Capturing Terminated | Warning | Packet capturing has been stopped during device re-initialization. | Restart the packet capture, as required. |
Packet Capture Complete | Warning | The device is near capacity. Packet captures might not capture all packets. | Verify the packet capture configuration and restart the packet capture, as required. |
Device DNS Server Connectivity Status | Warning | DNS server is {0} from the device. | Confirm the status of, and connectivity with, the configured DNS servers, and update the name resolution settings, as needed. |
SNMP Trap Received from Load Balancer | Warning | Load balancer "{0}" reported trap type "{1}". | |
Load Balancer Port Mode Change for {1} | Warning | Load balancer "{0}" reports operating mode for port "{1}" changed to "{2}". | |
Load Balancer Port HA Mode Change for {1} | Warning | Load balancer "{0}" reports port "{1}" HA mode changed. | |
Load Balancer HA Mode Change | Warning | Load balancer "{0}" reports HA mode change to "{1}". | |
Load Balancer HA Status Change | Warning | Load balancer "{0}" reports HA status change to "{1}". | |
Load Balancer Peer HA Status Change | Warning | Load balancer "{0}" reports peer HA status change to "{1}". | |
Load Balancer Port Load Balancing Mode Change for {1} | Warning | Load balancer "{0}" reports port "{1}" load balancing mode changed to "{3}" | |
I/O Module {0} Status Change | Warning | A {1} I/O module has been inserted into slot {0} on the device. A (full) Device reboot is required to make the new I/O module active. An I/O module has been removed from slot {0} on the device. Device reports I/O module {2} in slot {0}. | |
Hitless Reboot Status | Warning | The device was unable to complete a hitless reboot. It will perform a full reboot instead. | |
Device Auto-Recovery Status | Warning | The device was unable to complete auto-recovery. It will perform a full reboot instead. | |
Monitoring Configuration Mismatch | Warning | Device latency monitoring configuration requires Layer 2 pass-through monitoring to be enabled. | Disable moving device to Layer 2 bypass mode on high latency or enable Layer 2 pass-through monitoring. |
Device in High Latency Mode | Warning | Device high latency mode is currently {1}. Device high latency mode and Layer 2 bypass mode are currently {1}. | No explicit action is required. The device will attempt to automatically recover from the high latency condition. |
Device Reboot Required | Warning | The SSL decryption state and/or the number of flows allocated for decryption has changed on device {0}. (New flow value = {1}). A device reboot is required for the configuration to be updated. | Reboot the device for the configuration to be updated. |
Temperature Error | Warning | Device temperature is outside its normal range. | Check the cooling of your server room. Ensure there are no fan failures. Ensure the air used to cool the system is within the thermal specifications for the system (typically below 35°C). |